[Importance notice]
1. It may occur PSOD when installing Lenovo ESXi 6.7 U3 CI image (release in 12/17/2021) on ThinkSystem SN550/SN850/ST550 systems due to onboard network driver issue, it will be fixed by next Lenovo ESXi 6.7 U3 CI release. For more information, please refer to the TIP: https://datacentersupport.lenovo.com/us/en/solutions/ht513386
2. The release (12/17/2021) of Lenovo ESXi 6.7 U3 CI image does not support vSAN with VMD enabled Intel NVMe devices
--
[Storage Issue]
If hot-add or hot remove an Intel NVMe drive on AMD system, ESXi will PSOD. This problem is caused by the intel-nvme-vmd driver packaged in the CI image and will be fixed by a future release of such driver.
To avoid PSOD when hot-plug Intel NVMe drives, following workaround should be applied before hot-add/hot-remove:
The first workaround(no need reboot):
Run the following command to disable intel-nvme-vmd module:
# esxcli system module set --enabled=false --module=intel-nvme-vmd
The second workaround(need reboot):
Run the following command to remove the intel-nvme-vmd from ESXi:
# esxcli software vib remove -n intel-nvme-vmd
Removal Result
Message: The update completed successfully, but the system needs to be rebooted for the changes to be effective.
Reboot Required: true
VIBs Installed:
VIBs Removed: INT_bootbank_intel-nvme-vmd_2.6.0.1345-1OEM.700.1.0.15843807
VIBs Skipped:
#reboot
--
|
Best Recipe and Documentation |
03/19/2021 |
|
Best recipe and documentation for October 2021 release |
esxi_670_custom_vibs |
12/17/2021 |
|
ESXi 6.7 VIBs Repository for Lenovo System x and ThinkSystem |
esxi_700_components |
03/08/2022 |
|
ESXi 7.0 Components Repository for Lenovo System x and ThinkSystem |
Lenovo_Custom_ISO |
03/08/2022 |
|
ESXi Custom Images |