Lenovo Data Center Group
VMware ESXi Recipe
Targeted Server Family (Machine Type): Merged List of all supported devices (ANY) |
Targeted Operating System: VMware ESXi 6.0 |
VMware Recipe Creation Date: December 22, 2018 |
Lenovo VUM Repository and Custom Image |
Lenovo directly provides customers bundles and images of device drivers and utilities packaged to effectively interact with VMware‘s
system management tools. These management tools include: VMware Update Manager (VUM), esxcli or Power CLI.
 
| ||||||||
VMware Knowledge Database article on creating a local VUM Repo (useful to update servers without direct (or high speed connection to internet)) |
VMware Compatibility Guide Compliance |
Lenovo and our partners certify servers and devices comply with VMware‘s compatibility requirements.
In most cases, certified configurations require installation of drivers and firmware as a match pair. The tables below provide download
links to obtain drivers and firmware as well as links to VMware‘s Compatibility Guide. Download links also provide access to driver/firmware
release and change histroy information
Firmware Update Reference: Lenovo Firmware and Driver Update Best Practices |
ThinkSystem 1Gb 2-port RJ45 LOM (LAN on Motherboard) Card
|
Lenovo Part Number: 7ZT7A00544 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUKG | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | 4.00 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x37D1 | 0x17AA | 0x4020 | i40en | 1.7.5(600) |
Top of Page
ThinkSystem 1Gb 2-port RJ45 LOM (LAN on Motherboard) Card
|
Lenovo Part Number: 7ZT7A00544 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUKG | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | 4.00 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x37D1 | 0x17AA | 0x4021 | i40en | 1.7.5(600) |
Top of Page
ThinkSystem 1Gb 4-port RJ45 LOM (LAN on Motherboard) Card
|
Lenovo Part Number: 7ZT7A00545 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUKH | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | 4.00 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x37D1 | 0x17AA | 0x4021 | i40en | 1.7.5(600) |
Top of Page
ThinkSystem 10Gb 2-port SFP+ LOM (LAN on Motherboard) Card
|
Lenovo Part Number: 7ZT7A00546 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUKJ | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | 4.00 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x37D3 | 0x17AA | 0x4020 | i40en | 1.7.5(600) |
Top of Page
ThinkSystem 10Gb 2-port SFP+ LOM (LAN on Motherboard) Card
|
Lenovo Part Number: 7ZT7A00546 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUKJ | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | 4.00 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x37D3 | 0x17AA | 0x4021 | i40en | 1.7.5(600) |
Top of Page
ThinkSystem 10Gb 4-port SFP+ LOM (LAN on Motherboard) Card
|
Lenovo Part Number: 7ZT7A00547 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUKK | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | 4.00 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x37D3 | 0x17AA | 0x4021 | i40en | 1.7.5(600) |
Top of Page
ThinkSystem 10Gb 2-port Base-T LOM (LAN on Motherboard) Card
|
Lenovo Part Number: 7ZT7A00548 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUKL | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | 4.00 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x37D2 | 0x17AA | 0x4020 | i40en | 1.7.5(600) |
Top of Page
ThinkSystem 10Gb 2-port Base-T LOM (LAN on Motherboard) Card
|
Lenovo Part Number: 7ZT7A00548 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUKL | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | 4.00 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x37D2 | 0x17AA | 0x4021 | i40en | 1.7.5(600) |
Top of Page
ThinkSystem 10Gb 4-port Base-T LOM (LAN on Motherboard) Card
|
Lenovo Part Number: 7ZT7A00549 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUKM | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | 4.00 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x37D2 | 0x17AA | 0x4021 | i40en | 1.7.5(600) |
Top of Page
ThinkSystem D2 10Gb 8-port Base-T (RJ45)
|
Lenovo Part Number: 7M17A04000 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUY9 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 X722 SD530 FW Update Release for Linux | 6.80-4.00-sd530-d | 4.00 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x37D3 | 0x17AA | 0x4021 | i40en | 1.7.5(600) |
Top of Page
ThinkSystem D2 10Gb 8-port SFP+
|
Lenovo Part Number: 7M17A04001 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUYA | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 X722 SD530 FW Update Release for Linux | 6.80-4.00-sd530-d | 4.00 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x37D2 | 0x17AA | 0x4021 | i40en | 1.7.5(600) |
Top of Page
ThinkSystem SN850 LOM (LAN on Motherboard)
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: N/A | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | 4.00 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x37CE | 0x17AA | 0x4023 | i40en | 1.7.5(600) |
Top of Page
ThinkSystem SN550 LOM (LAN on Motherboard)
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: N/A | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | 4.00 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x37CE | 0x17AA | 0x4023 | i40en | 1.7.5(600) |
Top of Page
ThinkSystem ST550/558 LOM (LAN on Motherboard)
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: N/A | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | 4.00 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x37D1 | 0x17AA | 0x4022 | i40en | 1.7.5(600) |
Top of Page
ThinkSystem SR530/SR550/SR570/SR590 LOM (LAN on Motherboard)
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: N/A | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | 4.00 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x37D1 | 0x17AA | 0x4022 | i40en | 1.7.5(600) |
Top of Page
Flex System x280 LOM (LAN on Motherboard)
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: N/A | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE812 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE812 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE812 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Flex System x240 LOM (LAN on Motherboard)
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: N/A | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe11xxx UCNA Firmware Update for Linux - 12.0.1169.7 - Release 18B | 18b-oc11-12.0.1169.7-1 | 12.0.1169.7 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x19A2 | 0x0710 | 0x10DF | 0xE758 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0712 | 0x10DF | 0xE758 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0714 | 0x10DF | 0xE758 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Flex System x440 LOM (LAN on Motherboard)
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: N/A | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe11xxx UCNA Firmware Update for Linux - 12.0.1169.7 - Release 18B | 18b-oc11-12.0.1169.7-1 | 12.0.1169.7 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x19A2 | 0x0710 | 0x10DF | 0xE70F | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0712 | 0x10DF | 0xE70F | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0714 | 0x10DF | 0xE70F | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Flex System x280 LOM (LAN on Motherboard)
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: N/A | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE812 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE812 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE812 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Flex System x240 LOM (LAN on Motherboard)
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: N/A | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe11xxx UCNA Firmware Update for Linux - 12.0.1169.7 - Release 18B | 18b-oc11-12.0.1169.7-1 | 12.0.1169.7 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x19A2 | 0x0710 | 0x10DF | 0xE758 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0712 | 0x10DF | 0xE758 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0714 | 0x10DF | 0xE758 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Flex System x440 LOM (LAN on Motherboard)
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: N/A | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe11xxx UCNA Firmware Update for Linux - 12.0.1169.7 - Release 18B | 18b-oc11-12.0.1169.7-1 | 12.0.1169.7 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x19A2 | 0x0710 | 0x10DF | 0xE70F | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0712 | 0x10DF | 0xE70F | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0714 | 0x10DF | 0xE70F | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Flex System x280 LOM (LAN on Motherboard)
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: N/A | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE812 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE812 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE812 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Flex System x240 LOM (LAN on Motherboard)
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: N/A | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe11xxx UCNA Firmware Update for Linux - 12.0.1169.7 - Release 18B | 18b-oc11-12.0.1169.7-1 | 12.0.1169.7 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x19A2 | 0x0710 | 0x10DF | 0xE758 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0712 | 0x10DF | 0xE758 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0714 | 0x10DF | 0xE758 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Flex System x440 LOM (LAN on Motherboard)
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: N/A | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe11xxx UCNA Firmware Update for Linux - 12.0.1169.7 - Release 18B | 18b-oc11-12.0.1169.7-1 | 12.0.1169.7 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x19A2 | 0x0710 | 0x10DF | 0xE70F | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0712 | 0x10DF | 0xE70F | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0714 | 0x10DF | 0xE70F | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
System x3500 M5, x3550 M5, x3650 M5 LOM (LAN on Motherboard)
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: N/A | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Broadcom NX-1 Ethernet Firmware Update for Linux | nx1-212.0.5.4 | 212.0.5.4 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom NX1/NXE Ethernet VMware Drivers | 20180824-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x14E4 | 0x1657 | 0x17AA | 0x400E | net-tg3 | 3.137l.v60.1(600) |
Top of Page
System x NX360 M5 LOM (LAN on Motherboard)
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: N/A | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Broadcom NX-1 Ethernet Firmware Update for Linux | nx1-212.0.5.4 | 212.0.5.4 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom NX1/NXE Ethernet VMware Drivers | 20180824-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x14E4 | 0x1665 | 0x17AA | 0x4011 | net-tg3 | 3.137l.v60.1(600) |
Top of Page
System x3250 LOM (LAN on Motherboard)
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: N/A | ||||||||||||
Firmware | Device Firmware Included with Core System Firmware | |||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x1521 | 0x17AA | 0x4016 | igbn | 1.4.1(600) |
Top of Page
Wellsburg RAID Controller
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: N/A | ||||||||||||
Firmware | Device Firmware Included with Core System Firmware | |||||||||||
Drivers | All Device Drivers are included with VMware ESXi 6.0 image | Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||
VID | DID | SVID | SSID | |||||||||
SATA | 0x8086 | 0x2826 | Any | Any | vmw_ahci (Non-compliant Driver) |
Not found(INBOX) |
Top of Page
Wellsburg RAID Controller
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: N/A | ||||||||||||
Firmware | Device Firmware Included with Core System Firmware | |||||||||||
Drivers | All Device Drivers are included with VMware ESXi 6.0 image | Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||
VID | DID | SVID | SSID | |||||||||
SATA | 0x8086 | 0x2827 | Any | Any | vmw_ahci (Non-compliant Driver) |
Not found(INBOX) |
Top of Page
Intel VMD
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: N/A | ||||||||||||
Device Does Not Support VMware ESXi6.0 |
Top of Page
ThinkSystem RAID 530-8i PCIe 12Gb Adapter
|
Lenovo Part Number: 7Y37A01082 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUNG | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
ThinkSystem RAID 530-x Adapters update BIOS and Firmware for windows and linux | 530-50.5.0-1678 | 50.5.0-1678 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware vSphere Native Device Driver for Lenovo ThinkSystem RAID and ServeRAID | 20180822-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS/SATA-RAID | 0x1000 | 0x0017 | 0x1D49 | 0x0500 | lsi-mr3 | 7.705.09.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
ThinkSystem RAID 530-4i Flex Adapter
|
Lenovo Part Number: 7M17A03932 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AVEC | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
ThinkSystem RAID 530-x Adapters update BIOS and Firmware for windows and linux | 530-50.5.0-1678 | 50.5.0-1678 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware vSphere Native Device Driver for Lenovo ThinkSystem RAID and ServeRAID | 20180822-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS/SATA-RAID | 0x1000 | 0x001C | 0x1D49 | 0x0501 | lsi-mr3 | 7.705.09.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
ThinkSystem RAID 530-4i Flex Adapter
|
Lenovo Part Number: 7M27A03918 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUYR | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
ThinkSystem RAID 530-x Adapters update BIOS and Firmware for windows and linux | 530-50.5.0-1678 | 50.5.0-1678 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware vSphere Native Device Driver for Lenovo ThinkSystem RAID and ServeRAID | 20180822-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS/SATA-RAID | 0x1000 | 0x001C | 0x1D49 | 0x0501 | lsi-mr3 | 7.705.09.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
ThinkSystem RAID 530-8i Dense Adapter
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUYK | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
ThinkSystem RAID 530-x Adapters update BIOS and Firmware for windows and linux | 530-50.5.0-1678 | 50.5.0-1678 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware vSphere Native Device Driver for Lenovo ThinkSystem RAID and ServeRAID | 20180822-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS-SATA-NVME Tri-mode RAID | 0x1000 | 0x0017 | 0x1D49 | 0x0502 | lsi-mr3 | 7.705.09.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter
|
Lenovo Part Number: 7Y37A01083 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUNH | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter Update BIOS and Firmware for windows and linux | 730-24.21.0-0067-2 | 24.21.0-0067 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware vSphere Native Device Driver for Lenovo ThinkSystem RAID and ServeRAID | 20180822-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS | 0x1000 | 0x005D | 0x1D49 | 0x0600 | lsi-mr3 | 7.705.09.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter
|
Lenovo Part Number: 7Y37A01084 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUNJ | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
ThinkSystem RAID 930-x xGB Flash PCIe 12Gb Adapters2Gb Adapters update BIOS and Firmware for windows and linux | 930-50.5.0-1678 | 50.5.0-1678 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware vSphere Native Device Driver for Lenovo ThinkSystem RAID and ServeRAID | 20180822-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS/SATA-RAID | 0x1000 | 0x0016 | 0x1D49 | 0x0601 | lsi-mr3 | 7.705.09.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter
|
Lenovo Part Number: 7Y37A01085 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUNK | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
ThinkSystem RAID 930-x xGB Flash PCIe 12Gb Adapters2Gb Adapters update BIOS and Firmware for windows and linux | 930-50.5.0-1678 | 50.5.0-1678 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware vSphere Native Device Driver for Lenovo ThinkSystem RAID and ServeRAID | 20180822-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS/SATA-RAID | 0x1000 | 0x0014 | 0x1D49 | 0x0602 | lsi-mr3 | 7.705.09.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
ThinkSystem RAID 930-24i 4GB Flash PCIe 12Gb Adapter
|
Lenovo Part Number: 7Y37A01086 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUV1 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
ThinkSystem RAID 930-x xGB Flash PCIe 12Gb Adapters2Gb Adapters update BIOS and Firmware for windows and linux | 930-50.5.0-1678 | 50.5.0-1678 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware vSphere Native Device Driver for Lenovo ThinkSystem RAID and ServeRAID | 20180822-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS/SATA-RAID | 0x1000 | 0x0016 | 0x1D49 | 0x0603 | lsi-mr3 | 7.705.09.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter
|
Lenovo Part Number: 7Y37A01087 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUNQ | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
ThinkSystem RAID 930-x xGB Flash PCIe 12Gb Adapters2Gb Adapters update BIOS and Firmware for windows and linux | 930-50.5.0-1678 | 50.5.0-1678 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware vSphere Native Device Driver for Lenovo ThinkSystem RAID and ServeRAID | 20180822-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS/SATA-RAID | 0x1000 | 0x0014 | 0x1D49 | 0x0604 | lsi-mr3 | 7.705.09.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
ThinkSystem RAID 930-4i 2GB Flash Flex Adapter
|
Lenovo Part Number: 7M17A03933 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AVED | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
ThinkSystem RAID 930-x xGB Flash PCIe 12Gb Adapters2Gb Adapters update BIOS and Firmware for windows and linux | 930-50.5.0-1678 | 50.5.0-1678 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware vSphere Native Device Driver for Lenovo ThinkSystem RAID and ServeRAID | 20180822-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS/SATA-RAID | 0x1000 | 0x001B | 0x1D49 | 0x0605 | lsi-mr3 | 7.705.09.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
ThinkSystem RAID 930-4i 2GB Flash Flex Adapter
|
Lenovo Part Number: 7M27A03917 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUYS | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
ThinkSystem RAID 930-x xGB Flash PCIe 12Gb Adapters2Gb Adapters update BIOS and Firmware for windows and linux | 930-50.5.0-1678 | 50.5.0-1678 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware vSphere Native Device Driver for Lenovo ThinkSystem RAID and ServeRAID | 20180822-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS/SATA-RAID | 0x1000 | 0x001B | 0x1D49 | 0x0605 | lsi-mr3 | 7.705.09.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
ThinkSystem RAID 930-16i 8GB Flash PCIe 12Gb Adapter
|
Lenovo Part Number: 4Y37A09721 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B31E | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
ThinkSystem RAID 930-x xGB Flash PCIe 12Gb Adapters2Gb Adapters update BIOS and Firmware for windows and linux | 930-50.5.0-1678 | 50.5.0-1678 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware vSphere Native Device Driver for Lenovo ThinkSystem RAID and ServeRAID | 20180822-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS/SATA-RAID | 0x1000 | 0x0014 | 0x1D49 | 0x0607 | lsi-mr3 | 7.705.09.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
ServeRAID M1210 SAS/SATA Controller
|
Lenovo Part Number: 00JY194 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: ATPV | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
BIOS and Firmware Update for ServeRAID M1200 Series SAS/SATA Controllers | 1200-24.21.0-0067-2 | 4.680.01-8393 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware vSphere Native Device Driver for Lenovo ThinkSystem RAID and ServeRAID | 20180822-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS-RAID | 0x1000 | 0x005F | 0x1D49 | 0x04DB | lsi-mr3 | 7.705.09.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
ServeRAID M1215 SAS/SATA Controller
|
Lenovo Part Number: 46C9114 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A45W | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
BIOS and Firmware Update for ServeRAID M1200 Series SAS/SATA Controllers | 1200-24.21.0-0067-2 | 4.680.01-8393 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware vSphere Native Device Driver for Lenovo ThinkSystem RAID and ServeRAID | 20180822-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS-RAID | 0x1000 | 0x005F | 0x1014 | 0x0456 | lsi-mr3 | 7.705.09.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
Flex System x240 M5 LSI SAS3004 RAID Embedded Controller
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: N/A | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
BIOS and Firmware Update for ServeRAID M1200 Series SAS/SATA Controllers | 1200-24.21.0-0067-2 | 4.680.01-8393 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware vSphere Native Device Driver for Lenovo ThinkSystem RAID and ServeRAID | 20180822-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS-RAID | 0x1000 | 0x005F | 0x1D49 | 0x04AC | lsi-mr3 | 7.705.09.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
Flex System x280/x480/x880 X6 LSI SAS3004 RAID Embedded Controller
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: N/A | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
BIOS and Firmware Update for ServeRAID M1200 Series SAS/SATA Controllers | 1200-24.21.0-0067-2 | 4.680.01-8393 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware vSphere Native Device Driver for Lenovo ThinkSystem RAID and ServeRAID | 20180822-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS-RAID | 0x1000 | 0x005F | 0x1D49 | 0x04B4 | lsi-mr3 | 7.705.09.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
ServeRAID M5210 SAS/SATA Controller
|
Lenovo Part Number: 46C9110 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A3YZ | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
BIOS and Firmware Update for ServeRAID M5200 Series SAS/SATA Controllers | 5200-24.21.0-0067-2 | 4.680.01-8393 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware vSphere Native Device Driver for Lenovo ThinkSystem RAID and ServeRAID | 20180822-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS | 0x1000 | 0x005D | 0x1014 | 0x0454 | lsi-mr3 | 7.705.09.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
ServeRAID M5225-2GB SAS/SATA Controller
|
Lenovo Part Number: 00AE938 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A5ND | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
BIOS and Firmware Update for ServeRAID M5200 Series SAS/SATA Controllers | 5200-24.21.0-0067-2 | 4.680.01-8393 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware vSphere Native Device Driver for Lenovo ThinkSystem RAID and ServeRAID | 20180822-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS-RAID | 0x1000 | 0x005D | 0x1014 | 0x0455 | lsi-mr3 | 7.705.09.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
ServeRAID M5215 with 2GB Flash Enablement Flex System x240 M5
|
Lenovo Part Number: 00JX142 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A5SE | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
BIOS and Firmware Update for ServeRAID M5200 Series SAS/SATA Controllers | 5200-24.21.0-0067-2 | 4.680.01-8393 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware vSphere Native Device Driver for Lenovo ThinkSystem RAID and ServeRAID | 20180822-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS-RAID | 0x1000 | 0x005D | 0x1D49 | 0x045A | lsi-mr3 | 7.705.09.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
System x3750 M4 ServeRAID M5210e SAS/SATA Embedded Controller
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: N/A | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
BIOS and Firmware Update for ServeRAID M5200 Series SAS/SATA Controllers | 5200-24.21.0-0067-2 | 4.680.01-8393 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware vSphere Native Device Driver for Lenovo ThinkSystem RAID and ServeRAID | 20180822-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS-RAID | 0x1000 | 0x005D | 0x1D49 | 0x045C | lsi-mr3 | 7.705.09.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
ServeRAID M5120 SAS/SATA Controller
|
Lenovo Part Number: 81Y4478 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A1WX | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
ServeRAID M5100 Series SAS/SATA Controllers for Lenovo System x BIOS and Firmware Update | 6gb-23.34.0-0023-1 | 3.460.145-8209 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware vSphere Native Device Driver for Lenovo ThinkSystem RAID and ServeRAID | 20180822-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS-RAID | 0x1000 | 0x005B | 0x1014 | 0x040C | lsi-mr3 (Non-compliant Driver) |
7.705.09.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
IBM Flex System Storage Expansion Node
|
Lenovo Part Number: 68Y8588 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A3JF | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
ServeRAID M5100 Series SAS/SATA Controllers for Lenovo System x BIOS and Firmware Update | 6gb-23.34.0-0023-1 | 3.460.145-8209 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware vSphere Native Device Driver for Lenovo ThinkSystem RAID and ServeRAID | 20180822-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS-RAID | 0x1000 | 0x005B | 0x1014 | 0x0448 | lsi-mr3 (Non-compliant Driver) |
7.705.09.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
ServeRAID M5115 SAS/SATA Controller for Flex System
|
Lenovo Part Number: 90Y4390 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A2XW | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
ServeRAID M5100 Series SAS/SATA Controllers for Lenovo System x BIOS and Firmware Update | 6gb-23.34.0-0023-1 | 3.460.145-8209 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware vSphere Native Device Driver for Lenovo ThinkSystem RAID and ServeRAID | 20180822-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS-RAID | 0x1000 | 0x005B | 0x1014 | 0x041D | lsi-mr3 (Non-compliant Driver) |
7.705.09.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
ServeRAID M5100 Series IBM Flex System Flash Kit for X6
|
Lenovo Part Number: 44T1178 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A4DC | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
ServeRAID M5100 Series SAS/SATA Controllers for Lenovo System x BIOS and Firmware Update | 6gb-23.34.0-0023-1 | 3.460.145-8209 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware vSphere Native Device Driver for Lenovo ThinkSystem RAID and ServeRAID | 20180822-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS-RAID | 0x1000 | 0x005B | 0x1014 | 0x041D | lsi-mr3 (Non-compliant Driver) |
7.705.09.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
Flex System x240 LSI SAS2004 RAID Embedded Controller
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: N/A | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
LSI 2004 SAS Controller BIOS and Firmware Update for Lenovo Flex System x240 Compute Node | x240-1.20.05 | FW:--- | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Systemx SAS/HBA VMware ESXi (mpt2sas) Drivers | 20180415-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS | 0x1000 | 0x0070 | 0x1014 | 0x040E | lsiprovider (Support CIM) |
500.04.V0.65 | ||||||
scsi-mpt2sas (Non-compliant Driver) |
18.00.00.00.1vmw(INBOX) |
Top of Page
Flex System x440 LSI SAS2004 RAID Embedded Controller
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: N/A | ||||||||||||
No Device HCL |
Top of Page
ThinkSystem 430-8i SAS/SATA 12Gb HBA
|
Lenovo Part Number: 7Y37A01088 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUNL | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
BIOS and Firmware Update for ThinkSystem 430-x SAS/SATA 12Gb HBA(06.02.00.02) | 430-06.02.00.02 | 06.02.00.02 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Lenovo ThinkSystem SAS/HBA VMware ESXi Drivers | 20180605-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS | 0x1000 | 0x00AF | 0x1D49 | 0x0200 | lsi-msgpt35 | 06.00.00.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
ThinkSystem 430-16i SAS/SATA 12Gb HBA
|
Lenovo Part Number: 7Y37A01089 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUNM | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
BIOS and Firmware Update for ThinkSystem 430-x SAS/SATA 12Gb HBA(06.02.00.02) | 430-06.02.00.02 | 06.02.00.02 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Lenovo ThinkSystem SAS/HBA VMware ESXi Drivers | 20180605-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS | 0x1000 | 0x00AC | 0x1D49 | 0x0201 | lsi-msgpt35 | 06.00.00.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
ThinkSystem 430-8e SAS/SATA 12Gb HBA
|
Lenovo Part Number: 7Y37A01090 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUNR | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
BIOS and Firmware Update for ThinkSystem 430-x SAS/SATA 12Gb HBA(06.02.00.02) | 430-06.02.00.02 | 06.02.00.02 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Lenovo ThinkSystem SAS/HBA VMware ESXi Drivers | 20180605-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS | 0x1000 | 0x00AF | 0x1D49 | 0x0202 | lsi-msgpt35 | 06.00.00.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
ThinkSystem 430-16e SAS/SATA 12Gb HBA
|
Lenovo Part Number: 7Y37A01091 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUNN | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
BIOS and Firmware Update for ThinkSystem 430-x SAS/SATA 12Gb HBA(06.02.00.02) | 430-06.02.00.02 | 06.02.00.02 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Lenovo ThinkSystem SAS/HBA VMware ESXi Drivers | 20180605-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS | 0x1000 | 0x00AC | 0x1D49 | 0x0203 | lsi-msgpt35 | 06.00.00.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
ThinkSystem 430-8i SAS/SATA 12Gb Dense HBA
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B0SS | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
BIOS and Firmware Update for ThinkSystem 430-x SAS/SATA 12Gb HBA(06.02.00.02) | 430-06.02.00.02 | 06.02.00.02 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Lenovo ThinkSystem SAS/HBA VMware ESXi Drivers | 20180605-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS | 0x1000 | 0x00AF | 0x1D49 | 0x0204 | lsi-msgpt35 | 06.00.00.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.69 |
Top of Page
N2215 SAS/SATA HBA
|
Lenovo Part Number: 47C8675 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A3YY | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
BIOS/FW/UEFI Update for N2200 Series SAS/SATA HBA Controllers | n2200-1.15-7 | 15.00.02.00 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Systemx SAS/HBA VMware ESXi (mpt3sas) Device Drivers | 20180415-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS | 0x1000 | 0x0097 | 0x1014 | 0x0457 | lsi-msgpt3 | 16.00.00.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.65 |
Top of Page
N2225 SAS/SATA HBA
|
Lenovo Part Number: 00AE912 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A5M0 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
BIOS/FW/UEFI Update for N2200 Series SAS/SATA HBA Controllers | n2200-1.15-7 | 15.00.02.00 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Systemx SAS/HBA VMware ESXi (mpt3sas) Device Drivers | 20180415-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS | 0x1000 | 0x0097 | 0x1014 | 0x04BE | lsi-msgpt3 | 16.00.00.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.65 |
Top of Page
N2226 SAS/SATA HBA
|
Lenovo Part Number: 00AE916 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A5M1 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
BIOS/FW/UEFI Update for N2200 Series SAS/SATA HBA Controllers | n2200-1.15-7 | 15.00.02.00 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Systemx SAS/HBA VMware ESXi (mpt3sas) Device Drivers | 20180415-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS | 0x1000 | 0x0097 | 0x1014 | 0x04CD | lsi-msgpt3 | 16.00.00.00(600) | ||||||
lsiprovider (Support CIM) |
500.04.V0.65 |
Top of Page
N2125 SAS/SATA HBA
|
Lenovo Part Number: 46C9010 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A3MV | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
BIOS/FW/UEFI Update for N2125 SAS/SATA Controller | n2125-1.20.02-4 | FW:--- | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Systemx SAS/HBA VMware ESXi (mpt2sas) Drivers | 20180415-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS | 0x1000 | 0x0087 | 0x1014 | 0x0472 | lsiprovider (Support CIM) |
500.04.V0.65 | ||||||
scsi-mpt2sas (Non-compliant Driver) |
18.00.00.00.1vmw(INBOX) |
Top of Page
ThinkSystem M.2 Storage SATA Enablement Kit
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: N/A | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
ThinkSystem M.2 with Mirroring Enablement Kit Firmware Update For Anyos | 2.3.10.1098 | Unknown | ||||||||||
Drivers | All Device Drivers are included with VMware ESXi 6.0 image | Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||
VID | DID | SVID | SSID | |||||||||
SATA | 0x1B4B | 0x9230 | 0x1D49 | 0x0300 | ahci | 3.0-26vmw(INBOX) |
Top of Page
ThinkSystem NVMe Switch Adapters
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: N/A | ||||||||||||
Device Does Not Require Driver |
Top of Page
Lenovo ThinkSystem OCe14104B-NX PCIe 10Gb 4-Port SFP+ Ethernet Adapter By Emulex
|
Lenovo Part Number: 7ZT7A00493 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUKN | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE871 | elxnet | 12.0.1115.0(600) |
Top of Page
Emulex VFA5 ML2 Dual Port 10GbE SFP+ Adapter
|
Lenovo Part Number: 00D1996 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A40Q | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE810 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE810 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE810 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
IBM Flex System CN4058S 8-port 10Gb Virtual Fabric Adapter
|
Lenovo Part Number: 94Y5160 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A4R6 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE811 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE811 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE811 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
IBM Flex System CN4052 2-port 10Gb Virtual Fabric Adapter
|
Lenovo Part Number: 00JY800 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A5RP | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE815 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE815 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE815 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Flex System CN4054S 4-port 10Gb Virtual Fabric Adapter
|
Lenovo Part Number: 00AG590 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: ATBS | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE81A | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE81A | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE81A | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Flex System CN4052S 2-port 10Gb Virtual Fabric Adapter
|
Lenovo Part Number: 00AG540 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: ATBT | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE81B | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE81B | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE81B | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter
|
Lenovo Part Number: 00AG570 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AT7S | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE81C | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE81C | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE81C | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Emulex VFA5.2 ML2 2Port10GbE SFP+ Adapter w/FCoE
|
Lenovo Part Number: 01CV770 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AU7Z | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE874 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE874 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE874 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Emulex VFA5.2 ML2 Dual Port 10GbE SFP+ Adapter
|
Lenovo Part Number: 00AG560 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AT7U | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE81F | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE81F | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE81F | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Emulex VFA5.2 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW
|
Lenovo Part Number: 00AG580 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AT7T | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE81E | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE81E | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE81E | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Flex System CN4052S 2-port 10Gb Virtual Fabric Adapter Advanced
|
Lenovo Part Number: 01CV780 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AU7X | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE872 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE872 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE872 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Flex System CN4054S 4-port 10Gb Virtual Fabric Adapter Advanced
|
Lenovo Part Number: 01CV790 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AU7Y | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE873 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE873 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE873 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Emulex 10 GbE Virtual Fabric Adapter 5 Plus
|
Lenovo Part Number: 00JY830 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A5UU | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE818 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE818 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE818 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Emulex 10 GbE Virtual Fabric Adapter 5 Standard
|
Lenovo Part Number: 00JY820 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A5UT | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE816 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE816 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE816 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
IBM Flex System CN4054R 10Gb Virtual Fabric Adapter
|
Lenovo Part Number: 00Y3306 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A4K2 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe11xxx UCNA Firmware Update for Linux - 12.0.1169.7 - Release 18B | 18b-oc11-12.0.1169.7-1 | 12.0.1169.7 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x19A2 | 0x0710 | 0x10DF | 0xE731 | elxnet | 12.0.1115.0(600) | ||||||
FCoE CNAs | 0x19A2 | 0x0714 | 0x10DF | 0xE731 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Emulex Dual Port 10GbE SFP+ VFA IIIr
|
Lenovo Part Number: 00D8540 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A4XH | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe11xxx UCNA Firmware Update for Linux - 12.0.1169.7 - Release 18B | 18b-oc11-12.0.1169.7-1 | 12.0.1169.7 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x19A2 | 0x0710 | 0x10DF | 0xE72A | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x19A2 | 0x0712 | 0x10DF | 0xE72A | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x19A2 | 0x0714 | 0x10DF | 0xE72A | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Emulex VFA5 ML2 Dual Port 10GbE SFP+ Adapter
|
Lenovo Part Number: 00D1996 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A40Q | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE810 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE810 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE810 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
IBM Flex System CN4058S 8-port 10Gb Virtual Fabric Adapter
|
Lenovo Part Number: 94Y5160 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A4R6 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE811 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE811 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE811 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
IBM Flex System CN4052 2-port 10Gb Virtual Fabric Adapter
|
Lenovo Part Number: 00JY800 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A5RP | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE815 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE815 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE815 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Flex System CN4054S 4-port 10Gb Virtual Fabric Adapter
|
Lenovo Part Number: 00AG590 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: ATBS | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE81A | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE81A | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE81A | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Flex System CN4052S 2-port 10Gb Virtual Fabric Adapter
|
Lenovo Part Number: 00AG540 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: ATBT | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE81B | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE81B | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE81B | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter
|
Lenovo Part Number: 00AG570 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AT7S | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE81C | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE81C | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE81C | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Emulex VFA5.2 ML2 2Port10GbE SFP+ Adapter w/FCoE
|
Lenovo Part Number: 01CV770 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AU7Z | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE874 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE874 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE874 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Emulex VFA5.2 ML2 Dual Port 10GbE SFP+ Adapter
|
Lenovo Part Number: 00AG560 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AT7U | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE81F | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE81F | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE81F | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Emulex VFA5.2 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW
|
Lenovo Part Number: 00AG580 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AT7T | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE81E | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE81E | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE81E | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Flex System CN4052S 2-port 10Gb Virtual Fabric Adapter Advanced
|
Lenovo Part Number: 01CV780 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AU7X | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE872 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE872 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE872 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Flex System CN4054S 4-port 10Gb Virtual Fabric Adapter Advanced
|
Lenovo Part Number: 01CV790 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AU7Y | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE873 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE873 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE873 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Emulex 10 GbE Virtual Fabric Adapter 5 Plus
|
Lenovo Part Number: 00JY830 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A5UU | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE818 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE818 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE818 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Emulex 10 GbE Virtual Fabric Adapter 5 Standard
|
Lenovo Part Number: 00JY820 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A5UT | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE816 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE816 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE816 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
IBM Flex System CN4054R 10Gb Virtual Fabric Adapter
|
Lenovo Part Number: 00Y3306 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A4K2 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe11xxx UCNA Firmware Update for Linux - 12.0.1169.7 - Release 18B | 18b-oc11-12.0.1169.7-1 | 12.0.1169.7 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x19A2 | 0x0710 | 0x10DF | 0xE731 | elxnet | 12.0.1115.0(600) | ||||||
FCoE CNAs | 0x19A2 | 0x0714 | 0x10DF | 0xE731 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Emulex Dual Port 10GbE SFP+ VFA IIIr
|
Lenovo Part Number: 00D8540 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A4XH | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe11xxx UCNA Firmware Update for Linux - 12.0.1169.7 - Release 18B | 18b-oc11-12.0.1169.7-1 | 12.0.1169.7 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x19A2 | 0x0710 | 0x10DF | 0xE72A | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x19A2 | 0x0712 | 0x10DF | 0xE72A | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x19A2 | 0x0714 | 0x10DF | 0xE72A | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Emulex VFA5 ML2 Dual Port 10GbE SFP+ Adapter
|
Lenovo Part Number: 00D1996 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A40Q | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE810 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE810 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE810 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
IBM Flex System CN4058S 8-port 10Gb Virtual Fabric Adapter
|
Lenovo Part Number: 94Y5160 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A4R6 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE811 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE811 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE811 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
IBM Flex System CN4052 2-port 10Gb Virtual Fabric Adapter
|
Lenovo Part Number: 00JY800 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A5RP | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE815 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE815 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE815 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Flex System CN4054S 4-port 10Gb Virtual Fabric Adapter
|
Lenovo Part Number: 00AG590 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: ATBS | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE81A | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE81A | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE81A | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Flex System CN4052S 2-port 10Gb Virtual Fabric Adapter
|
Lenovo Part Number: 00AG540 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: ATBT | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE81B | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE81B | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE81B | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter
|
Lenovo Part Number: 00AG570 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AT7S | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE81C | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE81C | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE81C | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Emulex VFA5.2 ML2 2Port10GbE SFP+ Adapter w/FCoE
|
Lenovo Part Number: 01CV770 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AU7Z | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE874 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE874 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE874 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Emulex VFA5.2 ML2 Dual Port 10GbE SFP+ Adapter
|
Lenovo Part Number: 00AG560 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AT7U | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE81F | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE81F | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE81F | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Emulex VFA5.2 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW
|
Lenovo Part Number: 00AG580 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AT7T | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE81E | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE81E | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE81E | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Flex System CN4052S 2-port 10Gb Virtual Fabric Adapter Advanced
|
Lenovo Part Number: 01CV780 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AU7X | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE872 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE872 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE872 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Flex System CN4054S 4-port 10Gb Virtual Fabric Adapter Advanced
|
Lenovo Part Number: 01CV790 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AU7Y | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE873 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE873 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE873 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Emulex 10 GbE Virtual Fabric Adapter 5 Plus
|
Lenovo Part Number: 00JY830 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A5UU | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE818 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE818 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE818 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Emulex 10 GbE Virtual Fabric Adapter 5 Standard
|
Lenovo Part Number: 00JY820 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A5UT | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1169.12 - Release 18B | 18b-oc14-12.0.1169.12-2 | 12.0.1169.12 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x10DF | 0x0720 | 0x10DF | 0xE816 | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE816 | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE816 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
IBM Flex System CN4054R 10Gb Virtual Fabric Adapter
|
Lenovo Part Number: 00Y3306 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A4K2 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe11xxx UCNA Firmware Update for Linux - 12.0.1169.7 - Release 18B | 18b-oc11-12.0.1169.7-1 | 12.0.1169.7 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x19A2 | 0x0710 | 0x10DF | 0xE731 | elxnet | 12.0.1115.0(600) | ||||||
FCoE CNAs | 0x19A2 | 0x0714 | 0x10DF | 0xE731 | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
Emulex Dual Port 10GbE SFP+ VFA IIIr
|
Lenovo Part Number: 00D8540 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A4XH | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex OCe11xxx UCNA Firmware Update for Linux - 12.0.1169.7 - Release 18B | 18b-oc11-12.0.1169.7-1 | 12.0.1169.7 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom CCX (Emulex) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x19A2 | 0x0710 | 0x10DF | 0xE72A | elxnet | 12.0.1115.0(600) | ||||||
iSCSI | 0x19A2 | 0x0712 | 0x10DF | 0xE72A | elxnet (Support Driver) |
12.0.1115.0(600) | ||||||
ima-be2iscsi (Support Driver) |
12.0.1108.0(600) | |||||||||||
scsi-be2iscsi | 12.0.1108.0(600) | |||||||||||
FCoE CNAs | 0x19A2 | 0x0714 | 0x10DF | 0xE72A | brcmfcoe | 12.0.1115.0(600) | ||||||
elxnet (Support Driver) |
12.0.1115.0(600) |
Top of Page
IBM Flex System EN4132 2-port 10Gb Ethernet Adapter
|
Lenovo Part Number: 90Y3466 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A1QY | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Mellanox Firmware (18B) | 4.3-1.0.1.0.3 | FW:--- | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Mellanox Network VMware ESXi Device Drivers | 20181102-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x15B3 | 0x1003 | 0x15B3 | 0x0021 | nmlx4-core (Support Driver) |
3.15.11.6(600) | ||||||
nmlx4-en | 3.15.11.6(600) | |||||||||||
nmlx4-rdma (Support Driver) |
3.15.11.6(600) |
Top of Page
IBM Flex System EN6132 2-port 40Gb Ethernet Adapter
|
Lenovo Part Number: 90Y3482 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A3HK | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Mellanox Firmware (18B) | 4.3-1.0.1.0.3 | FW:--- | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Mellanox Network VMware ESXi Device Drivers | 20181102-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x15B3 | 0x1003 | 0x15B3 | 0x04A2 | nmlx4-core (Support Driver) |
3.15.11.6(600) | ||||||
nmlx4-en | 3.15.11.6(600) | |||||||||||
nmlx4-rdma (Support Driver) |
3.15.11.6(600) |
Top of Page
Mellanox ConnectX- 3 10 GbE Adapter
|
Lenovo Part Number: 00D9690 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A3PM | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Mellanox Firmware (18B) | 4.3-1.0.1.0.3 | FW:--- | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Mellanox Network VMware ESXi Device Drivers | 20181102-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x15B3 | 0x1003 | 0x15B3 | 0x0077 | nmlx4-core (Support Driver) |
3.15.11.6(600) | ||||||
nmlx4-en | 3.15.11.6(600) | |||||||||||
nmlx4-rdma (Support Driver) |
3.15.11.6(600) |
Top of Page
Mellanox ConnectX-3 FDR VPI IB/E Adapter
|
Lenovo Part Number: 00D9550 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A3PN | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Mellanox Firmware (18B) | 4.3-1.0.1.0.3 | FW:--- | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Mellanox Network VMware ESXi Device Drivers | 20181102-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x15B3 | 0x1003 | 0x15B3 | 0x0076 | nmlx4-core (Support Driver) |
3.15.11.6(600) | ||||||
nmlx4-en | 3.15.11.6(600) | |||||||||||
nmlx4-rdma (Support Driver) |
3.15.11.6(600) |
Top of Page
ThinkSystem Mellanox ConnectX-3 Mezz 40Gb 2-Port Ethernet Adapter
|
Lenovo Part Number: 7ZT7A00502 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AVCU | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Mellanox Firmware (18B) | 4.3-1.0.1.0.3 | FW:--- | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Mellanox Network VMware ESXi Device Drivers | 20181102-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x15B3 | 0x1003 | 0x15B3 | 0x04A2 | nmlx4-core (Support Driver) |
3.15.11.6(600) | ||||||
nmlx4-en | 3.15.11.6(600) | |||||||||||
nmlx4-rdma (Support Driver) |
3.15.11.6(600) |
Top of Page
Mellanox ConnectX-3 Pro ML2 2x40GbE/FDR VPI Adapter
|
Lenovo Part Number: 00FP650 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A5RK | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Mellanox Firmware (18B) | 4.3-1.0.1.0.3 | FW:--- | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Mellanox Network VMware ESXi Device Drivers | 20181102-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x15B3 | 0x1007 | 0x15B3 | 0x0032 | nmlx4-core (Support Driver) |
3.15.11.6(600) | ||||||
nmlx4-en | 3.15.11.6(600) | |||||||||||
nmlx4-rdma (Support Driver) |
3.15.11.6(600) |
Top of Page
ThinkSystem Mellanox ConnectX-3 Pro ML2 FDR 2-Port QSFP VPI Adapter
|
Lenovo Part Number: 7ZT7A00501 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUKR | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Mellanox Firmware (18B) | 4.3-1.0.1.0.3 | FW:--- | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Mellanox Network VMware ESXi Device Drivers | 20181102-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x15B3 | 0x1007 | 0x15B3 | 0x004E | nmlx4-core (Support Driver) |
3.15.11.6(600) | ||||||
nmlx4-en | 3.15.11.6(600) | |||||||||||
nmlx4-rdma (Support Driver) |
3.15.11.6(600) |
Top of Page
Mellanox ConnectX-4 Lx 1x40GbE QSFP+ Adapter
|
Lenovo Part Number: 00MM950 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: ATRN | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Mellanox Firmware (18B) | 4.3-1.0.1.0.3 | 14.22.4020 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Mellanox Network VMware ESXi Device Drivers | 20181102-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x15B3 | 0x1015 | 0x15B3 | 0x0018 | nmlx5-core | 4.15.12.12(600) |
Top of Page
Mellanox ConnectX-4 Lx ML2 1x25GbE SFP28 Adapter
|
Lenovo Part Number: 00MN990 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: ATZR | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Mellanox Firmware (18B) | 4.3-1.0.1.0.3 | 14.22.4020 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Mellanox Network VMware ESXi Device Drivers | 20181102-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x15B3 | 0x1015 | 0x15B3 | 0x0056 | nmlx5-core | 4.15.12.12(600) |
Top of Page
Mellanox ConnectX-4 Lx 2x25GbE PCIe Adapter
|
Lenovo Part Number: 01GR250 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUAJ | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Mellanox Firmware (18B) | 4.3-1.0.1.0.3 | 14.22.4020 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Mellanox Network VMware ESXi Device Drivers | 20181102-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x15B3 | 0x1015 | 0x15B3 | 0x0057 | nmlx5-core | 4.15.12.12(600) |
Top of Page
ThinkSystem Mellanox ConnectX-4 Lx ML2 25Gb 2-Port SFP28 Ethernet Adapter
|
Lenovo Part Number: 7ZT7A00507 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUKU | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Mellanox Firmware (18B) | 4.3-1.0.1.0.3 | 14.22.4020 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Mellanox Network VMware ESXi Device Drivers | 20181102-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x15B3 | 0x1015 | 0x15B3 | 0x0058 | nmlx5-core | 4.15.12.12(600) |
Top of Page
Mellanox ConnectX-4 2x100GbE / EDR IB QSFP28 VPI Adapter
|
Lenovo Part Number: 00MM960 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: ATRP | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Mellanox Firmware (18B) | 4.3-1.0.1.0.3 | 12.22.4020 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Mellanox Network VMware ESXi Device Drivers | 20181102-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x15B3 | 0x1013 | 0x15B3 | 0x0055 | nmlx5-core | 4.15.12.12(600) |
Top of Page
Mellanox ConnectX-4 EDR IB VPI Single-port x16 PCIe 3.0 HCA
|
Lenovo Part Number: 00KH924 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: ASWQ | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Mellanox Firmware (18B) | 4.3-1.0.1.0.3 | 12.22.4020 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Mellanox Network VMware ESXi Device Drivers | 20181102-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x15B3 | 0x1013 | 0x15B3 | 0x0042 | nmlx5-core | 4.15.12.12(600) |
Top of Page
ThinkSystem Mellanox ConnectX-4 PCIe FDR 2-Port QSFP VPI Adapter
|
Lenovo Part Number: 7ZT7A00500 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUVG | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Mellanox Firmware (18B) | 4.3-1.0.1.0.3 | 12.22.4020 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Mellanox Network VMware ESXi Device Drivers | 20181102-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x15B3 | 0x1013 | 0x15B3 | 0x0060 | nmlx5-core | 4.15.12.12(600) |
Top of Page
Mellanox ConnectX-4 PCIe FDR 1-Port QSFP VPI Adapter
|
Lenovo Part Number: 7XC7A05524 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B0WX | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Mellanox Firmware (18B) | 4.3-1.0.1.0.3 | 12.22.4020 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Mellanox Network VMware ESXi Device Drivers | 20181102-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x15B3 | 0x1013 | 0x15B3 | 0x0079 | nmlx5-core | 4.15.12.12(600) |
Top of Page
Broadcom Dual Port 10GbE SFP+ Adapter for IBM System x
|
Lenovo Part Number: 94Y5180 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A4Z6 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Online Qlogic NetXtreme II Firmware Utility | nx2-7.15.23.03 | 7.15.23.03 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
QLogic NXII driver for VMware | nx2-20180829-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x14E4 | 0x168E | 0x1014 | 0x04C6 | net-bnx2x | 2.713.60.v60.2(600) |
Top of Page
Broadcom NetXtreme Dual Port 10GbE BastT Adapter for IBM System x
|
Lenovo Part Number: 44T1370 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A5GZ | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Online Qlogic NetXtreme II Firmware Utility | nx2-7.15.23.03 | 7.15.23.03 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
QLogic NXII driver for VMware | nx2-20180829-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x14E4 | 0x168E | 0x1014 | 0x0492 | net-bnx2x | 2.713.60.v60.2(600) |
Top of Page
Broadcom NetXtreme II ML2 Dual Port 10GbaseT for IBM System x
|
Lenovo Part Number: 00D2026 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A40S | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Online Qlogic NetXtreme II Firmware Utility | nx2-7.15.23.03 | 7.15.23.03 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
QLogic NXII driver for VMware | nx2-20180829-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x14E4 | 0x168E | 0x1014 | 0x04A1 | net-bnx2x | 2.713.60.v60.2(600) |
Top of Page
Broadcom NetXtreme II ML2 Dual Port 10GbE SFP+ for IBM System x
|
Lenovo Part Number: 00D2028 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A40T | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Online Qlogic NetXtreme II Firmware Utility | nx2-7.15.23.03 | 7.15.23.03 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
QLogic NXII driver for VMware | nx2-20180829-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x14E4 | 0x168E | 0x1014 | 0x04A0 | net-bnx2x | 2.713.60.v60.2(600) |
Top of Page
Flex System EN4172 2-port 10Gb Ethernet Adapter
|
Lenovo Part Number: 00AG530 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A5RN | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Online Qlogic NetXtreme II Firmware Utility | nx2-7.15.23.03 | 7.15.23.03 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
QLogic NXII driver for VMware | nx2-20180829-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x14E4 | 0x16A1 | 0x1014 | 0x04D9 | net-bnx2x | 2.713.60.v60.2(600) |
Top of Page
ThinkSystem QLogic QL41134 PCIe 10Gb 4-Port Base-T Ethernet Adapter
|
Lenovo Part Number: 4XC7A08225 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B31G | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
QLogic FastLinQ Ethernet Adapter Firmware Update for Linux | ah-8.35.47-1 | 8.35.47 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
QLogic FastlinQ driver for VMware | fl-20180829-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x1077 | 0x8070 | 0x1077 | 0x0035 | qedentv | 3.9.31.0(600) | ||||||
Network | 0x1077 | 0x8090 | 0x1077 | 0x0035 | qedentv | 3.9.31.0(600) |
Top of Page
ThinkSystem QLogic QL45212 Flex 50Gb 2-Port Ethernet Adapter
|
Lenovo Part Number: 7XC7A05843 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B2VT | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
QLogic FastLinQ Ethernet Adapter Firmware Update for Linux | bb-8.35.47-1 | 8.35.47 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
QLogic FastlinQ driver for VMware | fl-20180829-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network Network | 0x1077 1077 | 0x1654 1654 | 0x1077 1077 | 0x0032 0032 | qedentv | 3.9.31.0(600) | ||||||
qedentv | 3.9.31.0(600) |
Top of Page
ThinkSystem QLogic QL45214 Flex 25Gb 4-Port Ethernet Adapter
|
Lenovo Part Number: 7XC7A05844 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B2VU | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
QLogic FastLinQ Ethernet Adapter Firmware Update for Linux | bb-8.35.47-1 | 8.35.47 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
QLogic FastlinQ driver for VMware | fl-20180829-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x1077 | 0x1654 | 0x1077 | 0x0033 | qedentv | 3.9.31.0(600) | ||||||
Network | 0x1077 | 0x1664 | 0x1077 | 0x0033 | qedentv | 3.9.31.0(600) |
Top of Page
ThinkSystem QLogic QL41134 PCIe 10Gb 4-Port Base-T Ethernet Adapter
|
Lenovo Part Number: 4XC7A08225 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B31G | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
QLogic FastLinQ Ethernet Adapter Firmware Update for Linux | ah-8.35.47-1 | 8.35.47 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
QLogic FastlinQ driver for VMware | fl-20180829-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x1077 | 0x8070 | 0x1077 | 0x0035 | qedentv | 3.9.31.0(600) | ||||||
Network | 0x1077 | 0x8090 | 0x1077 | 0x0035 | qedentv | 3.9.31.0(600) |
Top of Page
ThinkSystem QLogic QL45212 Flex 50Gb 2-Port Ethernet Adapter
|
Lenovo Part Number: 7XC7A05843 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B2VT | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
QLogic FastLinQ Ethernet Adapter Firmware Update for Linux | bb-8.35.47-1 | 8.35.47 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
QLogic FastlinQ driver for VMware | fl-20180829-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network Network | 0x1077 1077 | 0x1654 1654 | 0x1077 1077 | 0x0032 0032 | qedentv | 3.9.31.0(600) | ||||||
qedentv | 3.9.31.0(600) |
Top of Page
ThinkSystem QLogic QL45214 Flex 25Gb 4-Port Ethernet Adapter
|
Lenovo Part Number: 7XC7A05844 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B2VU | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
QLogic FastLinQ Ethernet Adapter Firmware Update for Linux | bb-8.35.47-1 | 8.35.47 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
QLogic FastlinQ driver for VMware | fl-20180829-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x1077 | 0x1654 | 0x1077 | 0x0033 | qedentv | 3.9.31.0(600) | ||||||
Network | 0x1077 | 0x1664 | 0x1077 | 0x0033 | qedentv | 3.9.31.0(600) |
Top of Page
IBM Flex System CN4022 2-port 10Gb Converged Adapter
|
Lenovo Part Number: 88Y5920 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A4K3 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Online Qlogic NetXtreme II Firmware Utility | nx2-7.15.23.03 | 7.15.23.03 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
QLogic NXII driver for VMware | nx2-20180829-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x14E4 | 0x16A1 | 0x1014 | 0x049F | net-bnx2x | 2.713.60.v60.2(600) | ||||||
iSCSI | 0x14E4 | 0x16A1 | 0x1014 | 0x049F | scsi-bnx2i | 2.713.60.v60.1(600) | ||||||
FCoE CNAs | 0x14E4 | 0x16A1 | 0x1014 | 0x049F | net-bnx2x | 2.713.60.v60.2(600) | ||||||
scsi-bnx2fc | 1.713.60.v60.1(600) |
Top of Page
IBM Flex System CN4022 2-port 10Gb Converged Adapter
|
Lenovo Part Number: 88Y5920 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A4K3 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Online Qlogic NetXtreme II Firmware Utility | nx2-7.15.23.03 | 7.15.23.03 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
QLogic NXII driver for VMware | nx2-20180829-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x14E4 | 0x16A1 | 0x1014 | 0x049F | net-bnx2x | 2.713.60.v60.2(600) | ||||||
iSCSI | 0x14E4 | 0x16A1 | 0x1014 | 0x049F | scsi-bnx2i | 2.713.60.v60.1(600) | ||||||
FCoE CNAs | 0x14E4 | 0x16A1 | 0x1014 | 0x049F | net-bnx2x | 2.713.60.v60.2(600) | ||||||
scsi-bnx2fc | 1.713.60.v60.1(600) |
Top of Page
IBM Flex System CN4022 2-port 10Gb Converged Adapter
|
Lenovo Part Number: 88Y5920 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A4K3 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Online Qlogic NetXtreme II Firmware Utility | nx2-7.15.23.03 | 7.15.23.03 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
QLogic NXII driver for VMware | nx2-20180829-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x14E4 | 0x16A1 | 0x1014 | 0x049F | net-bnx2x | 2.713.60.v60.2(600) | ||||||
iSCSI | 0x14E4 | 0x16A1 | 0x1014 | 0x049F | scsi-bnx2i | 2.713.60.v60.1(600) | ||||||
FCoE CNAs | 0x14E4 | 0x16A1 | 0x1014 | 0x049F | net-bnx2x | 2.713.60.v60.2(600) | ||||||
scsi-bnx2fc | 1.713.60.v60.1(600) |
Top of Page
ThinkSystem QLogic QL41262 PCIe 25Gb 2-Port SFP28 Ethernet Adapter
|
Lenovo Part Number: 4XC7A08228 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B21R | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
QLogic FastLinQ Ethernet Adapter Firmware Update for Linux | ah-8.35.47-1 | 8.35.47 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
QLogic FastlinQ driver for VMware | fl-20180829-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x1077 | 0x8070 | 0x1077 | 0x0039 | qedentv | 3.9.31.0(600) | ||||||
Network | 0x1077 | 0x8090 | 0x1077 | 0x0039 | qedentv | 3.9.31.0(600) | ||||||
FCoE CNAs | 0x1077 | 0x8080 | 0x1077 | 0x0039 | qedentv (Support Driver) |
3.9.31.0(600) | ||||||
qedf | 1.2.59.0(600) | |||||||||||
iSCSI | 0x1077 | 0x8084 | 0x1077 | 0x0039 | scsi-qedil | 1.2.13.0(600) |
Top of Page
ThinkSystem QLogic QL45262 Flex 50Gb 2-Port Ethernet Adapter with iSCSI/FcoE
|
Lenovo Part Number: 7XC7A05845 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B2VV | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
QLogic FastLinQ Ethernet Adapter Firmware Update for Linux | bb-8.35.47-1 | 8.35.47 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
QLogic FastlinQ driver for VMware | fl-20180829-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x1077 | 0x1654 | 0x1077 | 0x0034 | qedentv | 3.9.31.0(600) | ||||||
Network | 0x1077 | 0x1664 | 0x1077 | 0x0034 | qedentv | 3.9.31.0(600) | ||||||
FCoE CNAs | 0x1077 | 0x165C | 0x1077 | 0x0034 | qedentv (Support Driver) |
3.9.31.0(600) | ||||||
qedf | 1.2.59.0(600) | |||||||||||
iSCSI | 0x1077 | 0x165E | 0x1077 | 0x0034 | scsi-qedil | 1.2.13.0(600) |
Top of Page
ThinkSystem QLogic QL41262 PCIe 25Gb 2-Port SFP28 Ethernet Adapter
|
Lenovo Part Number: 4XC7A08228 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B21R | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
QLogic FastLinQ Ethernet Adapter Firmware Update for Linux | ah-8.35.47-1 | 8.35.47 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
QLogic FastlinQ driver for VMware | fl-20180829-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x1077 | 0x8070 | 0x1077 | 0x0039 | qedentv | 3.9.31.0(600) | ||||||
Network | 0x1077 | 0x8090 | 0x1077 | 0x0039 | qedentv | 3.9.31.0(600) | ||||||
FCoE CNAs | 0x1077 | 0x8080 | 0x1077 | 0x0039 | qedentv (Support Driver) |
3.9.31.0(600) | ||||||
qedf | 1.2.59.0(600) | |||||||||||
iSCSI | 0x1077 | 0x8084 | 0x1077 | 0x0039 | scsi-qedil | 1.2.13.0(600) |
Top of Page
ThinkSystem QLogic QL45262 Flex 50Gb 2-Port Ethernet Adapter with iSCSI/FcoE
|
Lenovo Part Number: 7XC7A05845 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B2VV | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
QLogic FastLinQ Ethernet Adapter Firmware Update for Linux | bb-8.35.47-1 | 8.35.47 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
QLogic FastlinQ driver for VMware | fl-20180829-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x1077 | 0x1654 | 0x1077 | 0x0034 | qedentv | 3.9.31.0(600) | ||||||
Network | 0x1077 | 0x1664 | 0x1077 | 0x0034 | qedentv | 3.9.31.0(600) | ||||||
FCoE CNAs | 0x1077 | 0x165C | 0x1077 | 0x0034 | qedentv (Support Driver) |
3.9.31.0(600) | ||||||
qedf | 1.2.59.0(600) | |||||||||||
iSCSI | 0x1077 | 0x165E | 0x1077 | 0x0034 | scsi-qedil | 1.2.13.0(600) |
Top of Page
ThinkSystem QLogic QL41262 PCIe 25Gb 2-Port SFP28 Ethernet Adapter
|
Lenovo Part Number: 4XC7A08228 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B21R | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
QLogic FastLinQ Ethernet Adapter Firmware Update for Linux | ah-8.35.47-1 | 8.35.47 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
QLogic FastlinQ driver for VMware | fl-20180829-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x1077 | 0x8070 | 0x1077 | 0x0039 | qedentv | 3.9.31.0(600) | ||||||
Network | 0x1077 | 0x8090 | 0x1077 | 0x0039 | qedentv | 3.9.31.0(600) | ||||||
FCoE CNAs | 0x1077 | 0x8080 | 0x1077 | 0x0039 | qedentv (Support Driver) |
3.9.31.0(600) | ||||||
qedf | 1.2.59.0(600) | |||||||||||
iSCSI | 0x1077 | 0x8084 | 0x1077 | 0x0039 | scsi-qedil | 1.2.13.0(600) |
Top of Page
ThinkSystem QLogic QL45262 Flex 50Gb 2-Port Ethernet Adapter with iSCSI/FcoE
|
Lenovo Part Number: 7XC7A05845 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B2VV | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
QLogic FastLinQ Ethernet Adapter Firmware Update for Linux | bb-8.35.47-1 | 8.35.47 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
QLogic FastlinQ driver for VMware | fl-20180829-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x1077 | 0x1654 | 0x1077 | 0x0034 | qedentv | 3.9.31.0(600) | ||||||
Network | 0x1077 | 0x1664 | 0x1077 | 0x0034 | qedentv | 3.9.31.0(600) | ||||||
FCoE CNAs | 0x1077 | 0x165C | 0x1077 | 0x0034 | qedentv (Support Driver) |
3.9.31.0(600) | ||||||
qedf | 1.2.59.0(600) | |||||||||||
iSCSI | 0x1077 | 0x165E | 0x1077 | 0x0034 | scsi-qedil | 1.2.13.0(600) |
Top of Page
ThinkSystem QLogic QL41262 PCIe 25Gb 2-Port SFP28 Ethernet Adapter
|
Lenovo Part Number: 4XC7A08228 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B21R | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
QLogic FastLinQ Ethernet Adapter Firmware Update for Linux | ah-8.35.47-1 | 8.35.47 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
QLogic FastlinQ driver for VMware | fl-20180829-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x1077 | 0x8070 | 0x1077 | 0x0039 | qedentv | 3.9.31.0(600) | ||||||
Network | 0x1077 | 0x8090 | 0x1077 | 0x0039 | qedentv | 3.9.31.0(600) | ||||||
FCoE CNAs | 0x1077 | 0x8080 | 0x1077 | 0x0039 | qedentv (Support Driver) |
3.9.31.0(600) | ||||||
qedf | 1.2.59.0(600) | |||||||||||
iSCSI | 0x1077 | 0x8084 | 0x1077 | 0x0039 | scsi-qedil | 1.2.13.0(600) |
Top of Page
ThinkSystem QLogic QL45262 Flex 50Gb 2-Port Ethernet Adapter with iSCSI/FcoE
|
Lenovo Part Number: 7XC7A05845 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B2VV | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
QLogic FastLinQ Ethernet Adapter Firmware Update for Linux | bb-8.35.47-1 | 8.35.47 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
QLogic FastlinQ driver for VMware | fl-20180829-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x1077 | 0x1654 | 0x1077 | 0x0034 | qedentv | 3.9.31.0(600) | ||||||
Network | 0x1077 | 0x1664 | 0x1077 | 0x0034 | qedentv | 3.9.31.0(600) | ||||||
FCoE CNAs | 0x1077 | 0x165C | 0x1077 | 0x0034 | qedentv (Support Driver) |
3.9.31.0(600) | ||||||
qedf | 1.2.59.0(600) | |||||||||||
iSCSI | 0x1077 | 0x165E | 0x1077 | 0x0034 | scsi-qedil | 1.2.13.0(600) |
Top of Page
Intel I350-F1 1xGbE Fiber Adapter
|
Lenovo Part Number: 00AG500 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A56K | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | NA | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x1522 | 0x8086 | 0x0005 | igbn | 1.4.1(600) |
Top of Page
Intel I350-T2 2xGbE BaseT Adapter for IBM System x
|
Lenovo Part Number: 00AG510 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A56L | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | NA | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x1521 | 0x8086 | 0x00A2 | igbn | 1.4.1(600) |
Top of Page
Intel I350-T4 4xGbE BaseT Adapter for IBM System x
|
Lenovo Part Number: 00AG520 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A56M | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | NA | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x1521 | 0x8086 | 0x00A1 | igbn | 1.4.1(600) |
Top of Page
Intel I350-T4 ML2 Quad Port GbE Adapter for IBM System x
|
Lenovo Part Number: 00D1998 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A40R | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | NA | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x1521 | 0x8086 | 0x1521 | igbn | 1.4.1(600) |
Top of Page
Intel Ethernet Dual Port Server Adapter I340-T2
|
Lenovo Part Number: 49Y4230 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: 5767 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | NA | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x1516 | 0x8086 | 0x12B2 | igbn (Non-compliant Driver) |
1.4.1(600) |
Top of Page
Intel Ethernet Quad Port Server Adapter I340-T4
|
Lenovo Part Number: 49Y4240 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: 5768 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | NA | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x150E | 0x8086 | 0x12A2 | igbn (Non-compliant Driver) |
1.4.1(600) |
Top of Page
ThinkSystem Intel I350-F1 PCIe 1Gb 1-Port SFP Ethernet Adapter
|
Lenovo Part Number: 7ZT7A00533 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUZZ | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | NA | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x1522 | 0x8086 | 0x0005 | igbn | 1.4.1(600) |
Top of Page
ThinkSystem Intel I350-T2 PCIe 1Gb 2-Port RJ45 Ethernet Adapter
|
Lenovo Part Number: 7ZT7A00534 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUZY | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | NA | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x1521 | 0x8086 | 0x00A2 | igbn | 1.4.1(600) |
Top of Page
ThinkSystem Intel I350-T4 PCIe 1Gb 4-Port RJ45 Ethernet Adapter
|
Lenovo Part Number: 7ZT7A00535 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUZW | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | NA | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x1521 | 0x8086 | 0x00A1 | igbn | 1.4.1(600) |
Top of Page
ThinkSystem Intel I350-T4 ML2 1Gb 4-Port RJ45 Ethernet Adapter
|
Lenovo Part Number: 7ZT7A00536 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUKW | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | NA | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x1521 | 0x8086 | 0x1521 | igbn | 1.4.1(600) |
Top of Page
Intel X520-DA2 Dual Port 10GbE SFP+ Adapter for IBM System x
|
Lenovo Part Number: 49Y7960 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A2EC | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | NA | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x10FB | 0x8086 | 0x7A12 | ixgben | 1.7.10(600) |
Top of Page
Intel X540-T2 Dual Port 10GBase-T Adapter for IBM System x
|
Lenovo Part Number: 49Y7970 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A2ED | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | NA | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x1528 | 0x8086 | 0x001A | ixgben | 1.7.10(600) |
Top of Page
Intel X540 ML2 Dual Port 10GbaseT Adapter for IBM System x
|
Lenovo Part Number: 00D1994 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A40P | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | NA | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x1528 | 0x8086 | 0x0000 | ixgben | 1.7.10(600) |
Top of Page
Intel X550-T1 Single Port 10GBase-T Adapter
|
Lenovo Part Number: 00MM850 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: ATRY | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | NA | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x15D1 | 0x8086 | 0x0021 | ixgben | 1.7.10(600) |
Top of Page
Intel X550-T2 Dual Port 10GBase-T Adapter
|
Lenovo Part Number: 00MM860 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: ATPX | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | NA | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x1563 | 0x8086 | 0x0022 | ixgben | 1.7.10(600) |
Top of Page
Intel X710 2x10GbE SFP+ Adapter for IBM System x
|
Lenovo Part Number: 01DA900 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AU2Y | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | 6.80 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x1572 | 0x8086 | 0x000A | i40en | 1.7.5(600) |
Top of Page
Intel X710 ML2 4x10GbE SFP+ Adapter for IBM System x
|
Lenovo Part Number: 94Y5200 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AS74 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | 6.80 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x1572 | 0x8086 | 0x0009 | i40en | 1.7.5(600) |
Top of Page
Intel X710-DA2 ML2 2x10GbE SFP+ adapter
|
Lenovo Part Number: 00JY940 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: ATRH | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | 6.80 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x1572 | 0x8086 | 0x000D | i40en | 1.7.5(600) |
Top of Page
Intel X710-DA2 2x10GbE SFP+ adapter
|
Lenovo Part Number: 7ZT7A00537 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUKX | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | 6.80 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x1572 | 0x8086 | 0x000A | i40en | 1.7.5(600) |
Top of Page
ThinkSystem Intel XXV710-DA2 PCIe 25Gb 2-Port SFP28 Ethernet Adapter
|
Lenovo Part Number: 7XC7A05523 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B0WY | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | 6.80 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x158B | 0x8086 | 0x4001 | i40en | 1.7.5(600) |
Top of Page
Intel X710-DA4 PCIe 4x10Gb SFP+ Adapter
|
Lenovo Part Number: 7XC7A05525 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B0YL | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | 6.80 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x1572 | 0x8086 | 0x4007 | i40en | 1.7.5(600) |
Top of Page
Intel X710-T4 PCIe 4x10Gb RJ45 Adapter
|
Lenovo Part Number: 7XC7A05927 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B0X1 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v23.2 Network FW Update Release for Linux | 6.80-4.00-1.1937.0-e | 6.80 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20180917-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x1589 | 0x8086 | 0x00A0 | i40en | 1.7.5(600) |
Top of Page
ThinkSystem Broadcom NetXtreme PCIe 1Gb 2-Port RJ45 Ethernet Adapter
|
Lenovo Part Number: 7ZT7A00482 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUZX | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Broadcom NX-1 Ethernet Firmware Update for Linux | nx1-212.0.5.4 | 212.0.5.4 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom NX1/NXE Ethernet VMware Drivers | 20180824-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x14E4 | 0x165F | 0x17AA | 0x402C | net-tg3 | 3.137l.v60.1(600) |
Top of Page
ThinkSystem Broadcom NetXtreme PCIe 1Gb 4-Port RJ45 Ethernet Adapter
|
Lenovo Part Number: 7ZT7A00484 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUZV | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Broadcom NX-1 Ethernet Firmware Update for Linux | nx1-212.0.5.4 | 212.0.5.4 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom NX1/NXE Ethernet VMware Drivers | 20180824-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x14E4 | 0x1657 | 0x17AA | 0x402D | net-tg3 | 3.137l.v60.1(600) |
Top of Page
IBM Flex System EN2024 4-port 1Gb Ethernet Adapter
|
Lenovo Part Number: 49Y7900 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A10Y | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Broadcom NX-1 Ethernet Firmware Update for Linux | nx1-212.0.5.4 | 212.0.5.4 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom NX1/NXE Ethernet VMware Drivers | 20180824-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x14E4 | 0x1656 | 0x14E4 | 0x1805 | net-tg3 | 3.137l.v60.1(600) |
Top of Page
IBM Flex System EN2024 4-port 1Gb Ethernet Adapter
|
Lenovo Part Number: 49Y7900 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A10Y | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Broadcom NX-1 Ethernet Firmware Update for Linux | nx1-212.0.5.4 | 212.0.5.4 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom NX1/NXE Ethernet VMware Drivers | 20180824-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x14E4 | 0x1656 | 0x14E4 | 0x2805 | net-tg3 | 3.137l.v60.1(600) |
Top of Page
Broadcom NetXtreme I Dual Port GbE Adapter
|
Lenovo Part Number: 90Y9370 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A2V4 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Broadcom NX-1 Ethernet Firmware Update for Linux | nx1-212.0.5.4 | 212.0.5.4 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom NX1/NXE Ethernet VMware Drivers | 20180824-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x14E4 | 0x165F | 0x1014 | 0x0450 | net-tg3 | 3.137l.v60.1(600) |
Top of Page
Broadcom NetXtreme I Quad Port GbE Adapter
|
Lenovo Part Number: 90Y9352 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A2V3 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Broadcom NX-1 Ethernet Firmware Update for Linux | nx1-212.0.5.4 | 212.0.5.4 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom NX1/NXE Ethernet VMware Drivers | 20180824-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x14E4 | 0x1657 | 0x1014 | 0x0420 | net-tg3 | 3.137l.v60.1(600) |
Top of Page
ThinkSystem Broadcom NX-E PCIe 10Gb 2-Port Base-T Ethernet Adapter
|
Lenovo Part Number: 7ZT7A00496 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUKP | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Broadcom NX-E Ethernet Firmware Update for Linux | nxe-212.0.168.0 | 212.0.168.0 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom NX1/NXE Ethernet VMware Drivers | 20180824-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x14E4 | 0x16D8 | 0x17AA | 0x4160 | bnxtnet | 212.0.93.0(600) |
Top of Page
ThinkSystem Broadcom NX-E ML2 10Gb 2-Port Base-T Ethernet Adapter
|
Lenovo Part Number: 7ZT7A00497 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUKQ | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Broadcom NX-E Ethernet Firmware Update for Linux | nxe-212.0.168.0 | 212.0.168.0 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom NX1/NXE Ethernet VMware Drivers | 20180824-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x14E4 | 0x16D8 | 0x17AA | 0x4161 | bnxtnet | 212.0.93.0(600) |
Top of Page
ThinkSystem Broadcom NX-C PCIe 25Gb 1-Port SFP28 Ethernet Adapter
|
Lenovo Part Number: 7ZT7A00505 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUKS | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Broadcom NX-E Ethernet Firmware Update for Linux | nxe-212.0.168.0 | 212.0.168.0 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom NX1/NXE Ethernet VMware Drivers | 20180824-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x14E4 | 0x16D6 | 0x17AA | 0x4120 | bnxtnet | 212.0.93.0(600) |
Top of Page
Emulex 16Gb Gen6 FC Single-port HBA
|
Lenovo Part Number: 01CV830 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: ATZU | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex HBA (LPe3100x) Firmware Update for Linux - 11.4.329.13 - Release 18A | 18a-lp3x-11.4.329.13-7 | 11.4.329.13 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom ECD (Emulex FC) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x10DF | 0xE300 | 0x10DF | 0xE333 | lpfc | 11.4.329.0(600) |
Top of Page
Emulex 16Gb Gen6 FC Dual-port HBA
|
Lenovo Part Number: 01CV840 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: ATZV | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex HBA (LPe3100x) Firmware Update for Linux - 11.4.329.13 - Release 18A | 18a-lp3x-11.4.329.13-7 | 11.4.329.13 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom ECD (Emulex FC) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x10DF | 0xE300 | 0x10DF | 0xE332 | lpfc | 11.4.329.0(600) |
Top of Page
ThinkSystem Emulex LPe32000-M2-L PCIe 32Gb 1-Port SFP+ Fibre Channel Adapter
|
Lenovo Part Number: 7ZT7A00517 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUNT | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex HBA (LPe3100x) Firmware Update for Linux - 11.4.329.13 - Release 18A | 18a-lp3x-11.4.329.13-7 | 11.4.329.13 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom ECD (Emulex FC) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x10DF | 0xE300 | 0x10DF | 0xE331 | lpfc | 11.4.329.0(600) |
Top of Page
ThinkSystem Emulex LPe32002-M2-L PCIe 32Gb 2-Port SFP+ Fibre Channel Adapter
|
Lenovo Part Number: 7ZT7A00519 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUNV | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex HBA (LPe3100x) Firmware Update for Linux - 11.4.329.13 - Release 18A | 18a-lp3x-11.4.329.13-7 | 11.4.329.13 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom ECD (Emulex FC) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x10DF | 0xE300 | 0x10DF | 0xE330 | lpfc | 11.4.329.0(600) |
Top of Page
ThinkSystem Emulex LPm16002B-L Mezz 16Gb 2-Port Fibre Channel Adapter
|
Lenovo Part Number: 7ZT7A00521 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AVCW | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex HBA (LPe1600x) Firmware Update for Linux - 11.4.329.13 - Release 18A | 18a-lp16-11.4.329.13-7 | 11.4.329.13 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom ECD (Emulex FC) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x10DF | 0xE200 | 0x10DF | 0xE288 | lpfc | 11.4.329.0(600) |
Top of Page
ThinkSystem Emulex LPm16004B-L Mezz 16Gb 4-Port Fibre Channel Adapter
|
Lenovo Part Number: 7ZT7A00522 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AVCX | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex HBA (LPe1600x) Firmware Update for Linux - 11.4.329.13 - Release 18A | 18a-lp16-11.4.329.13-7 | 11.4.329.13 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom ECD (Emulex FC) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x10DF | 0xE200 | 0x10DF | 0xE289 | lpfc | 11.4.329.0(600) |
Top of Page
IBM Flex System FC5052 2-port 16Gb FC Adapter
|
Lenovo Part Number: 95Y2386 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A45R | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex HBA (LPe1600x) Firmware Update for Linux - 11.4.329.13 - Release 18A | 18a-lp16-11.4.329.13-7 | 11.4.329.13 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom ECD (Emulex FC) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x10DF | 0xE200 | 0x10DF | 0xE202 | lpfc | 11.4.329.0(600) |
Top of Page
IBM Flex System FC5054 4-port 16Gb FC Adapter
|
Lenovo Part Number: 95Y2391 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A45S | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex HBA (LPe1600x) Firmware Update for Linux - 11.4.329.13 - Release 18A | 18a-lp16-11.4.329.13-7 | 11.4.329.13 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom ECD (Emulex FC) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x10DF | 0xE200 | 0x10DF | 0xE282 | lpfc | 11.4.329.0(600) |
Top of Page
Emulex 16Gb FC Single-port HBA
|
Lenovo Part Number: 81Y1655 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A2W5 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex HBA (LPe1600x) Firmware Update for Linux - 11.4.329.13 - Release 18A | 18a-lp16-11.4.329.13-7 | 11.4.329.13 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom ECD (Emulex FC) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x10DF | 0xE200 | 0x10DF | 0xE203 | lpfc | 11.4.329.0(600) |
Top of Page
Emulex 16Gb FC Dual-port HBA
|
Lenovo Part Number: 81Y1662 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A2W6 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex HBA (LPe1600x) Firmware Update for Linux - 11.4.329.13 - Release 18A | 18a-lp16-11.4.329.13-7 | 11.4.329.13 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom ECD (Emulex FC) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x10DF | 0xE200 | 0x10DF | 0xE204 | lpfc | 11.4.329.0(600) |
Top of Page
IBM Flex System FC3052 2-port 8Gb FC Adapter
|
Lenovo Part Number: 95Y2375 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A2N5 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex HBA (LPe1205/LPe1200x) Firmware Update for Linux - 2.10x6-11.40a13 - Release 18A | 18a-2.10x6-9 | 2.10x6 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom ECD (Emulex FC) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x10DF | 0xF100 | 0x10DF | 0xF130 | lpfc | 11.4.329.0(600) |
Top of Page
Emulex 8Gb FC Single-port HBA
|
Lenovo Part Number: 42D0485 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: 3580 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex HBA (LPe1205/LPe1200x) Firmware Update for Linux - 2.10x6-11.40a13 - Release 18A | 18a-2.10x6-9 | 2.10x6 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom ECD (Emulex FC) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x10DF | 0xF100 | 0x10DF | 0xF100 | lpfc | 11.4.329.0(600) |
Top of Page
Emulex 8Gb FC Dual-port HBA
|
Lenovo Part Number: 42D0494 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: 3581 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex HBA (LPe1205/LPe1200x) Firmware Update for Linux - 2.10x6-11.40a13 - Release 18A | 18a-2.10x6-9 | 2.10x6 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom ECD (Emulex FC) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x10DF | 0xF100 | 0x10DF | 0xF100 | lpfc | 11.4.329.0(600) |
Top of Page
Emulex 8Gb FC Single-port HBA
|
Lenovo Part Number: 4XC7A08220 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B0WZ | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex HBA (LPe1205/LPe1200x) Firmware Update for Linux - 2.10x6-11.40a13 - Release 18A | 18a-2.10x6-9 | 2.10x6 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom ECD (Emulex FC) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x10DF | 0xF100 | 0x10DF | 0xF140 | lpfc | 11.4.329.0(600) |
Top of Page
Emulex 8Gb FC Dual-port HBA
|
Lenovo Part Number: 4XC7A08221 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B0X0 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Emulex HBA (LPe1205/LPe1200x) Firmware Update for Linux - 2.10x6-11.40a13 - Release 18A | 18a-2.10x6-9 | 2.10x6 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom ECD (Emulex FC) VMware ESXi Device Drivers | 20180620-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x10DF | 0xF100 | 0x10DF | 0xF141 | lpfc | 11.4.329.0(600) |
Top of Page
QLogic 16Gb Enhanced Gen5 FC Single-port HBA
|
Lenovo Part Number: 01CV750 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: ATZB | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
QLogic Fibre Channel HBA Firmware Update for ThinkSystem | 1.90.53-2690-2742.d | 8.08.05 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Qlogic Fibre Channel VMware ESXi Device Drivers | 20181029-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x1077 | 0x2261 | 0x1077 | 0x02AE | qlnativefc | 2.1.65.0(600) |
Top of Page
QLogic 16Gb Enhanced Gen5 FC Dual-port HBA
|
Lenovo Part Number: 01CV760 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: ATZC | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
QLogic Fibre Channel HBA Firmware Update for ThinkSystem | 1.90.53-2690-2742.d | 8.08.05 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Qlogic Fibre Channel VMware ESXi Device Drivers | 20181029-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x1077 | 0x2261 | 0x1077 | 0x02AF | qlnativefc | 2.1.65.0(600) |
Top of Page
ThinkSystem QLogic QLE2740 PCIe 32Gb 1-Port SFP+ Fibre Channel Adapter
|
Lenovo Part Number: 7ZT7A00516 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUNS | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
QLogic Fibre Channel HBA Firmware Update for ThinkSystem | 1.90.53-2690-2742.d | 8.08.05 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Qlogic Fibre Channel VMware ESXi Device Drivers | 20181029-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x1077 | 0x2261 | 0x1077 | 0x02B2 | qlnativefc | 2.1.65.0(600) |
Top of Page
ThinkSystem QLogic QLE2742 PCIe 32Gb 2-Port SFP+ Fibre Channel Adapter
|
Lenovo Part Number: 7ZT7A00518 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUNU | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
QLogic Fibre Channel HBA Firmware Update for ThinkSystem | 1.90.53-2690-2742.d | 8.08.05 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Qlogic Fibre Channel VMware ESXi Device Drivers | 20181029-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x1077 | 0x2261 | 0x1077 | 0x02B3 | qlnativefc | 2.1.65.0(600) |
Top of Page
ThinkSystem QLogic QML2692 Mezz 16Gb 2-Port Fibre Channel Adapter
|
Lenovo Part Number: 7ZT7A00520 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AVCV | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
QLogic Fibre Channel HBA Firmware Update for ThinkSystem | 1.90.53-2690-2742.d | 8.08.05 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Qlogic Fibre Channel VMware ESXi Device Drivers | 20181029-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x1077 | 0x2261 | 0x1077 | 0x02B4 | qlnativefc | 2.1.65.0(600) |
Top of Page
Qlogic 16Gb FC Single-port HBA for IBM System x
|
Lenovo Part Number: 00Y3337 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A3KW | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
QLogic 16Gb Fibre Channel Adapter MultiFlash Update for System x for 00Y3337-00Y3344 | 266x-4.74.13.d | 8.08.05 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Qlogic Fibre Channel VMware ESXi Device Drivers | 20181029-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x1077 | 0x2031 | 0x1077 | 0x0264 | qlnativefc | 2.1.65.0(600) |
Top of Page
Qlogic 16Gb FC Dual-port HBA for IBM System x
|
Lenovo Part Number: 00Y3341 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A3KX | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
QLogic 16Gb Fibre Channel Adapter MultiFlash Update for System x for 00Y3337-00Y3344 | 266x-4.74.13.d | 8.08.05 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Qlogic Fibre Channel VMware ESXi Device Drivers | 20181029-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x1077 | 0x2031 | 0x1077 | 0x0263 | qlnativefc | 2.1.65.0(600) |
Top of Page
QLogic 8Gb FC Single-port HBA for IBM System x
|
Lenovo Part Number: 42D0501 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: 3578 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Qlogic Update for 8G FC - Multiboot Update for System x | 8g-mb4.10.08.c | 8.08.01 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Qlogic Fibre Channel VMware ESXi Device Drivers | 20181029-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x1077 | 0x2532 | 0x1077 | 0x015C | qlnativefc | 2.1.65.0(600) |
Top of Page
QLogic 8Gb FC Dual-port HBA for IBM System x
|
Lenovo Part Number: 42D0510 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: 3579 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Qlogic Update for 8G FC - Multiboot Update for System x | 8g-mb4.10.08.c | 8.08.01 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Qlogic Fibre Channel VMware ESXi Device Drivers | 20181029-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x1077 | 0x2532 | 0x1077 | 0x015D | qlnativefc | 2.1.65.0(600) |
Top of Page
IBM Flex System FC 5172 2-port 16Gb FC Adapter (Qlogic)
|
Lenovo Part Number: 69Y1942 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A1BQ | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Lenovo Flex System FC5172 2-port 16Gb FC Multiboot Update Package | 4.75.10-16g-fxd | 8.08.05 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Qlogic Fibre Channel VMware ESXi Device Drivers | 20181029-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x1077 | 0x2031 | 0x1077 | 0x0240 | qlnativefc | 2.1.65.0(600) |
Top of Page
IBM Flex System FC3172 2-port 8Gb FC Adapter (Qlogic)
|
Lenovo Part Number: 69Y1938 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: A1BM | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Lenovo Flex System FC3172 2-port 8Gb FC Multiboot Update Package | 4.11af-8g-flex.p | 8.08.01 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Qlogic Fibre Channel VMware ESXi Device Drivers | 20181029-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x1077 | 0x2532 | 0x1077 | 0x0175 | qlnativefc | 2.1.65.0(600) |
Top of Page
Lenovo Data Center Group VMware OS Support Home Page |