Lenovo Data Center Group
VMware ESXi Recipe
Server Family (Machine Type): ThinkSystem ST50 (7Y48,7Y49,7Y50)
Server Product Guide |
Targeted Operating System: VMware ESXi 6.5 | Known Server Limitations/Issues and Solutions |
VMware Recipe Creation Date: May 18, 2020 |
Lenovo VUM Repository and Custom Image |
Lenovo directly provides customers bundles and images of device drivers and utilities packaged to effectively interact with VMware‘s
system management tools. These management tools include: VMware Update Manager (VUM), esxcli or Power CLI.
 
| ||||||||
VMware Knowledge Database article on creating a local VUM Repo (useful to update servers without direct (or high speed connection to internet)) |
VMware Compatibility Guide Compliance |
Lenovo and our partners certify servers and devices comply with VMware‘s compatibility requirements.
In most cases, certified configurations require installation of drivers and firmware as a match pair. The tables below provide download
links to obtain drivers and firmware as well as links to VMware‘s Compatibility Guide. Download links also provide access to driver/firmware
release and change histroy information
Firmware Update Reference: Lenovo Firmware and Driver Update Best Practices |
Intel VMD
|
Lenovo Part Number: N/A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: N/A | ||||||||||||
Device Does Not Support VMware ESXi6.5 |
Top of Page
ThinkSystem RAID 530-8i PCIe 12Gb Adapter
|
Lenovo Part Number: 7Y37A01082 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUNG | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
ThinkSystem RAID 530-x Adapters update BIOS and Firmware (For Linux) | mr3.5.530-51.10.0-3038-2 | 51.10.0-3038 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware vSphere Native Device Driver for Lenovo RAID and ServeRAID (For VMWare) | mr3-20191128-2 | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS/SATA-RAID | 0x1000 | 0x0017 | 0x1D49 | 0x0500 | lsi-mr3 (Non-compliant Driver) |
7.710.07.00(650) | ||||||
lsiprovider (Support CIM) |
50.00.V0.74 |
Top of Page
ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter
|
Lenovo Part Number: 7Y37A01083 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUNH | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
ThinkSystem RAID 730-8i PCIe 12Gb Adapter Update BIOS and Firmware (For Linux) | mr3.0.730-24.21.0-0124-2 | 24.21.0-0124 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware vSphere Native Device Driver for Lenovo RAID and ServeRAID (For VMWare) | mr3-20191128-2 | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS | 0x1000 | 0x005D | 0x1D49 | 0x0600 | lsi-mr3 (Non-compliant Driver) |
7.710.07.00(650) | ||||||
lsiprovider (Support CIM) |
50.00.V0.74 |
Top of Page
ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter
|
Lenovo Part Number: 7Y37A01084 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUNJ | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
ThinkSystem RAID 930-x xGB Flash PCIe 12Gb Adapters2Gb Adapters update BIOS and Firmware (For Linux) | mr3.5.930-51.10.0-3038-2 | 51.10.0-3038 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware vSphere Native Device Driver for Lenovo RAID and ServeRAID (For VMWare) | mr3-20191128-2 | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS/SATA-RAID | 0x1000 | 0x0016 | 0x1D49 | 0x0601 | lsi-mr3 (Non-compliant Driver) |
7.710.07.00(650) | ||||||
lsiprovider (Support CIM) |
50.00.V0.74 |
Top of Page
ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter
|
Lenovo Part Number: 7Y37A01087 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUNQ | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
ThinkSystem RAID 930-x xGB Flash PCIe 12Gb Adapters2Gb Adapters update BIOS and Firmware (For Linux) | mr3.5.930-51.10.0-3038-2 | 51.10.0-3038 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware vSphere Native Device Driver for Lenovo RAID and ServeRAID (For VMWare) | mr3-20191128-2 | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS/SATA-RAID | 0x1000 | 0x0014 | 0x1D49 | 0x0604 | lsi-mr3 (Non-compliant Driver) |
7.710.07.00(650) | ||||||
lsiprovider (Support CIM) |
50.00.V0.74 |
Top of Page
ThinkSystem 430-8i SAS/SATA 12Gb HBA
|
Lenovo Part Number: 7Y37A01088 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUNL | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
ThinkSystem 430-x SAS/SATA 12Gb HBA update BIOS and Firmware (For Linux) | mpt3.5.430-11.02.00.00-2 | 11.02.00.00 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Lenovo SAS/HBA VMware ESXi Drivers | 20190904-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS | 0x1000 | 0x00AF | 0x1D49 | 0x0200 | lsi-msgpt35 (Non-compliant Driver) |
11.00.00.00(650) | ||||||
lsiprovider (Support CIM) |
50.00.V0.74 |
Top of Page
ThinkSystem 430-8e SAS/SATA 12Gb HBA
|
Lenovo Part Number: 7Y37A01090 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUNR | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
ThinkSystem 430-x SAS/SATA 12Gb HBA update BIOS and Firmware (For Linux) | mpt3.5.430-11.02.00.00-2 | 11.02.00.00 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Lenovo SAS/HBA VMware ESXi Drivers | 20190904-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS | 0x1000 | 0x00AF | 0x1D49 | 0x0202 | lsi-msgpt35 (Non-compliant Driver) |
11.00.00.00(650) | ||||||
lsiprovider (Support CIM) |
50.00.V0.74 |
Top of Page
ThinkSystem Intel I350-T2 PCIe 1Gb 2-Port RJ45 Ethernet Adapter
|
Lenovo Part Number: 7ZT7A00534 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUZY | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v24.1 Network FW Update Release for Linux | 7.00-4.10-1.2203.0-all-b | NA | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20190723-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x1521 | 0x8086 | 0x00A2 | igbn | 1.4.10(600) |
Top of Page
ThinkSystem Intel I350-T4 PCIe 1Gb 4-Port RJ45 Ethernet Adapter
|
Lenovo Part Number: 7ZT7A00535 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUZW | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v24.1 Network FW Update Release for Linux | 7.00-4.10-1.2203.0-all-b | NA | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20190723-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x1521 | 0x8086 | 0x00A1 | igbn | 1.4.10(600) |
Top of Page
Intel X550-T1 Single Port 10GBase-T Adapter
|
Lenovo Part Number: 00MM850 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: ATRY | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v24.1 Network FW Update Release for Linux | 7.00-4.10-1.2203.0-all-b | NA | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20190723-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x15D1 | 0x8086 | 0x0021 | ixgben | 1.7.20(600) |
Top of Page
Intel X550-T2 Dual Port 10GBase-T Adapter
|
Lenovo Part Number: 00MM860 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: ATPX | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v24.1 Network FW Update Release for Linux | 7.00-4.10-1.2203.0-all-b | NA | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20190723-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x1563 | 0x8086 | 0x0022 | ixgben | 1.7.20(600) |
Top of Page
Intel X710-DA4 PCIe 4x10Gb SFP+ Adapter
|
Lenovo Part Number: 7XC7A05525 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B0YL | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Intel v24.1 Network FW Update Release for Linux | 7.00-4.10-1.2203.0-all-b | 7.00 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
VMware drivers package release for Intel Ethernet | 20190723-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x8086 | 0x1572 | 0x8086 | 0x4007 | i40en | 1.8.6(650) |
Top of Page
ThinkSystem Broadcom NetXtreme PCIe 1Gb 2-Port RJ45 Ethernet Adapter
|
Lenovo Part Number: 7ZT7A00482 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUZX | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Broadcom NX-1 Ethernet Firmware Update for Linux (For Linux) | nx1-214.0.6.2 | 214.0.6.2 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom NX1/NXE Ethernet VMware Drivers | 20190726-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x14E4 | 0x165F | 0x17AA | 0x402C | ntg3 | 4.1.3.2-1vmw(INBOX) |
Top of Page
ThinkSystem Broadcom NetXtreme PCIe 1Gb 4-Port RJ45 Ethernet Adapter
|
Lenovo Part Number: 7ZT7A00484 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUZV | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Broadcom NX-1 Ethernet Firmware Update for Linux (For Linux) | nx1-214.0.6.2 | 214.0.6.2 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom NX1/NXE Ethernet VMware Drivers | 20190726-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x14E4 | 0x1657 | 0x17AA | 0x402D | ntg3 | 4.1.3.2-1vmw(INBOX) |
Top of Page
ThinkSystem Broadcom NX-E PCIe 10Gb 2-Port Base-T Ethernet Adapter
|
Lenovo Part Number: 7ZT7A00496 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUKP | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version |
Device Firmware Version | |||||||||
Broadcom NX-E Ethernet Firmware Update for Linux | nxe-214.0.286.17-1 | 214.0.286.17 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom NX1/NXE Ethernet VMware Drivers | 20190726-vc | |||||||||||
Device Function (VMware HCL link) |
PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Network | 0x14E4 | 0x16D8 | 0x17AA | 0x4160 | bnxtnet | 214.0.230.0(650) |
Top of Page
Lenovo Data Center Group VMware OS Support Home Page |
https://vmware.lenovo.com |