[Storage Issue]
If hot-add or hot remove an Intel NVMe drive on AMD system, ESXi will PSOD. This problem is caused by the intel-nvme-vmd driver packaged in the CI image and will be fixed by a future release of such driver. To avoid PSOD when hot-plug Intel NVMe drives, following workaround should be applied before hot-add/hot-remove:

The first workaround(no need reboot):

 Run the following command to disable intel-nvme-vmd module:
 # esxcli system module set --enabled=false --module=intel-nvme-vmd

The second workaround(need reboot):

 Run the following command to remove the intel-nvme-vmd from ESXi:
 # esxcli software vib remove -n intel-nvme-vmd
  Removal Result
  Message: The update completed successfully, but the system needs to be rebooted for the changes to be effective.
  Reboot Required: true
  VIBs Installed:
  VIBs Removed: INT_bootbank_intel-nvme-vmd_2.6.0.1345-1OEM.700.1.0.15843807
  VIBs Skipped:
 #reboot