Lenovo Data Center Group
VMware ESXi Recipe
Server Family (Machine Type): ThinkSystem ST558 (7Y15, 7Y16) Server Product Guide |
Processor Family: Intel Xeon Gold 6200/5200, Silver 4200, Bronze 3200, Platinum 8200 (Cascade-Lake-SP) Series |
Targeted Operating System: VMware ESXi 7.0 | Known Server Limitations/Issues and Solutions |
VMware Recipe Creation Date: November 01, 2023 |
Lenovo VUM Repository and Custom Image |
Lenovo directly provides customers bundles and images of device drivers and utilities packaged to effectively interact with VMware‘ssystem management tools. These management tools include: VMware Update Manager (VUM), esxcli or Power CLI.  
| ||||
VMware Knowledge Database article on creating a local VUM Repo (useful to update servers without direct (or high speed connection to internet)) |
VMware Compatibility Guide Compliance |
Lenovo and our partners certify servers and devices comply with VMware‘s compatibility requirements.In most cases, certified configurations require installation of drivers and firmware as a match pair. The tables below provide downloadlinks to obtain drivers and firmware as well as links to VMware‘s Compatibility Guide. Download links also provide access to driver/firmwarerelease and change histroy information
|
Reference Materials |
Firmware Update Reference: Lenovo Firmware and Driver Update Best Practices |
UEFI settings for virtualization: Optimal Hypervisor Performance Lenovo Server Settings |
Inventory of Updates |
Core System Firmware | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
XClarity Provisioning Manager | Lenovo Firmware Package Version | | ||||||||||
Lenovo XClarity Provisioning Manager | pdl146d-2.10 | |||||||||||
System BIOS/UEFI | Lenovo Firmware Package Version | | ||||||||||
Lenovo System UEFI/BIOS Firmware - Lenovo Support U | o0e182m-4.11 | |||||||||||
XClarity Controller | Lenovo Firmware Package Version | | ||||||||||
Lenovo XClarity Controller | cdi3b2n-9.86 |
Emulex VFA5.2 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW | Lenovo Part Number: 00AG580 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AT7T | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1317.7 - Release | oc.14-12.0.1317.7-9 | 12.0.1317.7 | ||||||||||
Drivers | All Device Drivers are included with VMware ESXi 7.0 image | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
FCoE CNAs | 0x10DF | 0x0724 | 0x10DF | 0xE81E | brcmfcoe vib in install distro | 12.0.1500.0-1vmw | elxnet Required Support vib vib in install distro | No HCL entry | ||||
iSCSI | 0x10DF | 0x0722 | 0x10DF | 0xE81E | elx-esx-libelxima.so Required Support vib vib in install distro | No HCL entry | elxiscsi vib in install distro | 12.0.1200.0-2vmw | elxnet Required Support vib vib in install distro | No HCL entry | ||
Networking | 0x10DF | 0x0720 | 0x10DF | 0xE81E | elxnet vib in install distro | 12.0.1250.0-5vmw |
Back to Index
Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter | Lenovo Part Number: 00AG570 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AT7S | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1317.7 - Release | oc.14-12.0.1317.7-9 | 12.0.1317.7 | ||||||||||
Drivers | All Device Drivers are included with VMware ESXi 7.0 image | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Networking | 0x10DF | 0x0720 | 0x10DF | 0xE81C | elxnet vib in install distro | 12.0.1250.0-5vmw |
Back to Index
Lenovo ThinkSystem OCe14104B-NX PCIe 10Gb 4-Port SFP+ Ethernet Adapter By Emulex | Lenovo Part Number: 7ZT7A00493 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUKP | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Emulex OCe14xxx UCNA Firmware Update for Linux - 12.0.1317.7 - Release | oc.14-12.0.1317.7-9 | 12.0.1317.7 | ||||||||||
Drivers | All Device Drivers are included with VMware ESXi 7.0 image | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Networking | 0x10DF | 0x0720 | 0x10DF | 0xE871 | elxnet vib in install distro | 12.0.1250.0-5vmw |
Back to Index
Emulex 16Gb Gen6 FC Dual-port HBA | Lenovo Part Number: 01CV840 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: ATZV | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Emulex Fibre Channel | lp.31-14.2.594.10-2 | 14.2.594.10 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
No DS number available | lp-20230612-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x10DF | 0xE300 | 0x10DF | 0xE332 | lpfc | 14.2.567.0 |
Back to Index
Emulex 16Gb Gen6 FC Single-port HBA | Lenovo Part Number: 01CV830 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: ATZU | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Emulex Fibre Channel | lp.31-14.2.594.10-2 | 14.2.594.10 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
No DS number available | lp-20230612-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x10DF | 0xE300 | 0x10DF | 0xE333 | lpfc | 14.2.567.0 |
Back to Index
ThinkSystem Broadcom 57414 10/25GbE SFP28 2-port PCIe Ethernet Adapter | Lenovo Part Number: 4XC7A08238 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B5T0 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Broadcom NetXtreme E | nxe-225.1.103.0-6 | 225.1.103.0 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom NetXtreme E | nxe-20230310-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Networking | 0x14E4 | 0x16D7 | 0x17AA | 0x4105 | bnxtnet | 225.0.131.0 |
Back to Index
ThinkSystem Broadcom 5720 1GbE RJ45 2-Port PCIe Ethernet Adapter | Lenovo Part Number: 7ZT7A00482 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUZV | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Broadcom NetXtreme | nx1-225.0.3.1-4 | 225.0.3.1 | ||||||||||
Drivers | All Device Drivers are included with VMware ESXi 7.0 image | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Networking | 0x14E4 | 0x1657 | 0x17AA | 0x402D | ntg3 vib in install distro | 4.1.4.1-1vmw |
Back to Index
ThinkSystem Broadcom 5719 1GbE RJ45 4-Port PCIe Ethernet Adapter | Lenovo Part Number: 7ZT7A00484 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUKN | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Broadcom NetXtreme | nx1-225.0.3.1-4 | 225.0.3.1 | ||||||||||
Drivers | All Device Drivers are included with VMware ESXi 7.0 image | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Networking | 0x14E4 | 0x1657 | 0x17AA | 0x402D | ntg3 vib in install distro | 4.1.4.1-1vmw |
Back to Index
ThinkSystem Broadcom 57416 10GBASE-T 2-Port PCIe Ethernet Adapter | Lenovo Part Number: 7ZT7A00496 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUKQ | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Broadcom NetXtreme E | nxe-225.1.103.0-6 | 225.1.103.0 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Broadcom NetXtreme E | nxe-20230310-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Networking | 0x14E4 | 0x16D8 | 0x17AA | 0x4160 | bnxtnet | 225.0.131.0 |
Back to Index
Intel X550-T1 Single Port 10GBase-T Adapter | Lenovo Part Number: 00MM850 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: ATRY | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Intel Networking Adapter/Device Linux Firmware - Lenovo Support U | net-9.2-6.2-1.3357.0-2 | Query Error | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
No DS number available | net-20230918-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Networking | 0x8086 | 0x15D1 | 0x8086 | 0x0021 | ixgben Non compliant | 1.14.2.0 |
Back to Index
ThinkSystem Intel X710-DA2 PCIe 10Gb 2-Port SFP+ Ethernet Adapter | Lenovo Part Number: 7ZT7A00537 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUKX | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Intel Networking Adapter/Device Linux Firmware - Lenovo Support U | net-9.2-6.2-1.3357.0-2 | 9.2 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
No DS number available | net-20230918-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Networking | 0x8086 | 0x1572 | 0x8086 | 0x000A | i40en Non compliant | 2.4.2.0 |
Back to Index
ThinkSystem Intel I350-F1 PCIe 1Gb 1-Port SFP Ethernet Adapter | Lenovo Part Number: 7ZT7A00533 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUZZ | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Intel Networking Adapter/Device Linux Firmware - Lenovo Support U | net-9.2-6.2-1.3357.0-2 | 1.3218.0 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
No DS number available | net-20230918-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Networking | 0x8086 | 0x1522 | 0x8086 | 0x0005 | igbn | 1.11.2.0 |
Back to Index
ThinkSystem Intel I350-T2 PCIe 1Gb 2-Port RJ45 Ethernet Adapter | Lenovo Part Number: 7ZT7A00534 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUZY | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Intel Networking Adapter/Device Linux Firmware - Lenovo Support U | net-9.2-6.2-1.3357.0-2 | 1.3218.0 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
No DS number available | net-20230918-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Networking | 0x8086 | 0x1521 | 0x8086 | 0x00A2 | igbn | 1.11.2.0 |
Back to Index
ThinkSystem Intel I350-T4 PCIe 1Gb 4-Port RJ45 Ethernet Adapter | Lenovo Part Number: 7ZT7A00535 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUZW | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Intel Networking Adapter/Device Linux Firmware - Lenovo Support U | net-9.2-6.2-1.3357.0-2 | 1.3218.0 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
No DS number available | net-20230918-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Networking | 0x8086 | 0x1521 | 0x8086 | 0x00A1 | igbn | 1.11.2.0 |
Back to Index
ThinkSystem Intel XXV710-DA2 PCIe 25Gb 2-Port SFP28 Ethernet Adapter | Lenovo Part Number: 7XC7A05523 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B0WY | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Intel Networking Adapter/Device Linux Firmware - Lenovo Support U | net-9.2-6.2-1.3357.0-2 | 9.2 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
No DS number available | net-20230918-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Networking | 0x8086 | 0x158B | 0x8086 | 0x4001 | i40en Non compliant | 2.4.2.0 |
Back to Index
ThinkSystem ST550/558 LOM | Lenovo Part Number: | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: Miss | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Intel Networking Adapter/Device Linux Firmware - Lenovo Support U | net-9.2-6.2-1.3357.0-2 | 6.2 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
No DS number available | net-20230918-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Networking | 0x8086 | 0x37D1 | 0x17AA | 0x4022 | i40en Non compliant | 2.4.2.0 |
Back to Index
ThinkSystem Intel X710-T4L 10GBASE-T 4-Port PCIe Ethernet Adapter | Lenovo Part Number: 4XC7A79699 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: BMXB | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Intel Networking Adapter/Device Linux Firmware - Lenovo Support U | net-9.2-6.2-1.3357.0-2 | 9.2 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
No DS number available | net-20230918-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Networking | 0x8086 | 0x15FF | 0x8086 | 0x4019 | i40en Non compliant | 2.4.2.0 |
Back to Index
Intel X550-T2 Dual Port 10GBase-T Adapter | Lenovo Part Number: 00MM860 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: ATPX | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Intel Networking Adapter/Device Linux Firmware - Lenovo Support U | net-9.2-6.2-1.3357.0-2 | Query Error | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
No DS number available | net-20230918-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Networking | 0x8086 | 0x1563 | 0x8086 | 0x0022 | ixgben Non compliant | 1.14.2.0 |
Back to Index
ThinkSystem 430-16i SAS/SATA 12Gb HBA | Lenovo Part Number: 7Y37A01089 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUNM | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Lenovo Storage Host-Bus-Adapter | mpt3.5.430-23.02.00.00-0 | 23.02.00.00 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Lenovo Storage Devices Storage Host-Bus-Adapte | mpt3.5-20221104-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS | 0x1000 | 0x00AC | 0x1D49 | 0x0201 | lsiprovider Required Support vib | 700.00.V0.82 | lsi-msgpt35 | 23.00.00.00 |
Back to Index
ThinkSystem 430-8e SAS/SATA 12Gb HBA | Lenovo Part Number: 7Y37A01090 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUNR | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Lenovo Storage Host-Bus-Adapter | mpt3.5.430-23.02.00.00-0 | 23.02.00.00 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Lenovo Storage Devices Storage Host-Bus-Adapte | mpt3.5-20221104-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS | 0x1000 | 0x00AF | 0x1D49 | 0x0202 | lsiprovider Required Support vib | 700.00.V0.82 | lsi-msgpt35 | 23.00.00.00 |
Back to Index
ThinkSystem 430-8i SAS/SATA 12Gb HBA | Lenovo Part Number: 7Y37A01088 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUNL | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Lenovo Storage Host-Bus-Adapter | mpt3.5.430-23.02.00.00-0 | 23.02.00.00 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Lenovo Storage Devices Storage Host-Bus-Adapte | mpt3.5-20221104-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS | 0x1000 | 0x00AF | 0x1D49 | 0x0200 | lsiprovider Required Support vib | 700.00.V0.82 | lsi-msgpt35 | 23.00.00.00 |
Back to Index
ThinkSystem M.2 with Mirroring Enablement Kit | Lenovo Part Number: 7Y37A01093 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUZX | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Lenovo ThinkSystem M.2 with Mirroring Enablement Kit | sata-2.3.10.1103-0 | 2.3.10.1212 | ||||||||||
Drivers | All Device Drivers are included with VMware ESXi 7.0 image | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
bootstore-sata | 0x1B4B | 0x9230 | 0x1D49 | 0x0300 | vmw_ahci vib in install distro | 2.0.9-1vmw |
Back to Index
ThinkSystem RAID 530-8i PCIe 12Gb Adapter | Lenovo Part Number: 7Y37A01082 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUNG | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Lenovo RAID Adapter Linux Firmware - Lenovo Support U | mr3.5.530-51.22.0-4634-2 | 51.22.0-4634 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Lenovo Storage Devices RAID Adapter VMware Driver - Lenovo Support U | mr3-20221104-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS/SATA-RAID | 0x1000 | 0x0017 | 0x1D49 | 0x0500 | lsiprovider Required Support vib | 700.00.V0.82 | lsi-mr3 | 7.722.02.00 |
Back to Index
ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter | Lenovo Part Number: 7Y37A01083 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUNH | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Lenovo RAID Adapter Linux Firmware - Lenovo Support U | mr3.0.730-24.21.0-0151-6 | 24.21.0-0151 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Lenovo Storage Devices RAID Adapter VMware Driver - Lenovo Support U | mr3-20221104-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS-RAID | 0x1000 | 0x005D | 0x1D49 | 0x0600 | lsiprovider Required Support vib | 700.00.V0.82 | lsi-mr3 Non compliant | 7.722.02.00 |
Back to Index
ThinkSystem RAID 730-8i 2GB Flash PCIe 12Gb Adapter | Lenovo Part Number: 4Y37A09722 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B4RQ | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Lenovo RAID Adapter Linux Firmware - Lenovo Support U | mr3.0.730-24.21.0-0151-6 | 24.21.0-0151 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Lenovo Storage Devices RAID Adapter VMware Driver - Lenovo Support U | mr3-20221104-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS-RAID | 0x1000 | 0x005D | 0x1D49 | 0x0608 | lsiprovider Required Support vib | 700.00.V0.82 | lsi-mr3 Non compliant | 7.722.02.00 |
Back to Index
ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter | Lenovo Part Number: 7Y37A01085 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUNK | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
No DS number available | mr3.5.930-51.22.0-5096-2 | 51.22.0-5096 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Lenovo Storage Devices RAID Adapter VMware Driver - Lenovo Support U | mr3-20221104-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS/SATA-RAID | 0x1000 | 0x0014 | 0x1D49 | 0x0602 | lsiprovider Required Support vib | 700.00.V0.82 | lsi-mr3 | 7.722.02.00 |
Back to Index
ThinkSystem RAID 930-24i 4GB Flash PCIe 12Gb Adapter | Lenovo Part Number: 7Y37A01086 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUV1 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
No DS number available | mr3.5.930-51.22.0-5096-2 | 51.22.0-5096 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Lenovo Storage Devices RAID Adapter VMware Driver - Lenovo Support U | mr3-20221104-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS/SATA-RAID | 0x1000 | 0x0016 | 0x1D49 | 0x0603 | lsiprovider Required Support vib | 700.00.V0.82 | lsi-mr3 | 7.722.02.00 |
Back to Index
ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter | Lenovo Part Number: 7Y37A01087 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUNQ | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
No DS number available | mr3.5.930-51.22.0-5096-2 | 51.22.0-5096 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Lenovo Storage Devices RAID Adapter VMware Driver - Lenovo Support U | mr3-20221104-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS/SATA-RAID | 0x1000 | 0x0014 | 0x1D49 | 0x0604 | lsiprovider Required Support vib | 700.00.V0.82 | lsi-mr3 | 7.722.02.00 |
Back to Index
ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter | Lenovo Part Number: 7Y37A01084 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUNJ | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
No DS number available | mr3.5.930-51.22.0-5096-2 | 51.22.0-5096 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Lenovo Storage Devices RAID Adapter VMware Driver - Lenovo Support U | mr3-20221104-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS/SATA-RAID | 0x1000 | 0x0016 | 0x1D49 | 0x0601 | lsiprovider Required Support vib | 700.00.V0.82 | lsi-mr3 | 7.722.02.00 |
Back to Index
ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Adapter | Lenovo Part Number: 4Y37A09730 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: BC4U | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Lenovo RAID Adapter Linux Firmware - Lenovo Support U | mr3.5.940-52.22.0-5052-0 | 52.22.0-5052 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Lenovo Storage Devices RAID Adapter VMware Driver - Lenovo Support U | mr3.x40-20221019-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS-SATA-NVME Tri-mode | 0x1000 | 0x10E2 | 0x1D49 | 0x060C | lsiprovider Required Support vib | 700.00.V0.82 | lsi-mr3 | 7.722.02.00 |
Back to Index
ThinkSystem RAID 940-16i 4GB Flash PCIe Gen4 12Gb Adapter | Lenovo Part Number: 4Y37A78600 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: BMM1 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Lenovo RAID Adapter Linux Firmware - Lenovo Support U | mr3.5.940-52.22.0-5052-0 | 52.22.0-5052 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Lenovo Storage Devices RAID Adapter VMware Driver - Lenovo Support U | mr3.x40-20221019-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS-SATA-NVME Tri-mode | 0x1000 | 0x10E2 | 0x1D49 | 0x0610 | lsiprovider Required Support vib | 700.00.V0.82 | lsi-mr3 | 7.722.02.00 |
Back to Index
ThinkSystem RAID 940-8e 4GB Flash PCIe Gen4 12Gb Adapter | Lenovo Part Number: 4Y37A78836 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: BNWJ | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Lenovo RAID Adapter Linux Firmware - Lenovo Support U | mr3.5.940-52.22.0-5052-0 | 52.22.0-5052 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Lenovo Storage Devices RAID Adapter VMware Driver - Lenovo Support U | mr3.x40-20221019-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS-SATA-NVME Tri-mode | 0x1000 | 0x10E2 | 0x1D49 | 0x060F | lsiprovider Required Support vib | 700.00.V0.82 | lsi-mr3 | 7.722.02.00 |
Back to Index
ThinkSystem RAID 940-32i 8GB Flash PCIe Gen4 12Gb Adapter | Lenovo Part Number: 4Y37A09733 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B8P8 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Lenovo RAID Adapter Linux Firmware - Lenovo Support U | mr3.5.940-52.22.0-5052-0 | 52.22.0-5052 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Lenovo Storage Devices RAID Adapter VMware Driver - Lenovo Support U | mr3.x40-20221019-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS/SATA-RAID | 0x1000 | 0x10E2 | 0x1D49 | 0x060E | lsiprovider Required Support vib | 700.00.V0.82 | lsi-mr3 | 7.722.02.00 |
Back to Index
ThinkSystem RAID 540-8i PCIe Gen4 12Gb Adapter | Lenovo Part Number: 4Y37A78834 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: Miss | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Lenovo RAID Adapter Linux Firmware - Lenovo Support U | mr3.5.540-52.22.0-4775-2 | 52.22.0-4775 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Lenovo Storage Devices RAID Adapter VMware Driver - Lenovo Support U | mr3.x40-20221019-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS/SATA-RAID | 0x1000 | 0x10E6 | 0x1D49 | 0x0505 | lsiprovider Required Support vib | 700.00.V0.82 | lsi-mr3 | 7.722.02.00 |
Back to Index
ThinkSystem 440-8i SAS/SATA PCIe Gen4 12Gb HBA | Lenovo Part Number: 4Y37A78601 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: BMM2 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Lenovo Storage Host-Bus-Adapter | mpt3.5.440-23.125.17.00-2 | 23.125.17.00 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Lenovo Storage Devices Storage Host-Bus-Adapte | mpt3.5.x40-20221019-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS | 0x1000 | 0x00E6 | 0x1D49 | 0x0207 | lsiprovider Required Support vib | 700.00.V0.82 | lsi-msgpt35 | 23.00.00.00 |
Back to Index
ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb HBA | Lenovo Part Number: 4Y37A78602 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: BMM3 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Lenovo Storage Host-Bus-Adapter | mpt3.5.440-23.125.17.00-2 | 23.125.17.00 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Lenovo Storage Devices Storage Host-Bus-Adapte | mpt3.5.x40-20221019-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS | 0x1000 | 0x00E6 | 0x1D49 | 0x0208 | lsiprovider Required Support vib | 700.00.V0.82 | lsi-msgpt35 | 23.00.00.00 |
Back to Index
ThinkSystem 440-8e SAS/SATA PCIe Gen4 12Gb HBA | Lenovo Part Number: 4Y37A78837 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: Miss | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Lenovo Storage Host-Bus-Adapter | mpt3.5.440-23.125.17.00-2 | 23.125.17.00 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Lenovo Storage Devices Storage Host-Bus-Adapte | mpt3.5.x40-20221019-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS | 0x1000 | 0x00E6 | 0x1D49 | 0x0209 | lsiprovider Required Support vib | 700.00.V0.82 | lsi-msgpt35 | 23.00.00.00 |
Back to Index
ThinkSystem RAID 930-16i 8GB Flash PCIe 12Gb Adapter | Lenovo Part Number: 4Y37A09721 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B31E | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
No DS number available | mr3.5.930-51.22.0-5096-2 | 51.22.0-5096 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Lenovo Storage Devices RAID Adapter VMware Driver - Lenovo Support U | mr3-20221104-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS/SATA-RAID | 0x1000 | 0x0014 | 0x1D49 | 0x0607 | lsiprovider Required Support vib | 700.00.V0.82 | lsi-mr3 | 7.722.02.00 |
Back to Index
ThinkSystem RAID 940-8i 4GB Flash PCIe Gen4 12Gb Adapter | Lenovo Part Number: 4Y37A09728 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B8NY | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Lenovo RAID Adapter Linux Firmware - Lenovo Support U | mr3.5.940-52.22.0-5052-0 | 52.22.0-5052 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Lenovo Storage Devices RAID Adapter VMware Driver - Lenovo Support U | mr3.x40-20221019-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS-SATA-NVME Tri-mode | 0x1000 | 0x10E2 | 0x1D49 | 0x060A | lsiprovider Required Support vib | 700.00.V0.82 | lsi-mr3 | 7.722.02.00 |
Back to Index
ThinkSystem RAID 930-24i 4GB Flash PCIe 12Gb Adapter | Lenovo Part Number: 7Y37A01086 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: AUV1 | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
No DS number available | mr3.5.930-51.22.0-5096-2 | 51.22.0-5096 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Lenovo Storage Devices RAID Adapter VMware Driver - Lenovo Support U | mr3-20221104-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS/SATA-RAID | 0x1000 | 0x0016 | 0x1D49 | 0x0603 | lsiprovider Required Support vib | 700.00.V0.82 | lsi-mr3 | 7.722.02.00 |
Back to Index
All Supported NVMe Drives | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | ||||||||||
Lenovo Storage Linux Firmware - Lenovo Support U | all-1.50.30-0 |
All Supported SAS Drives | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | ||||||||||
Lenovo Storage Linux Firmware - Lenovo Support U | all-1.50.30-0 |
All Supported SATA Drives | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | ||||||||||
Lenovo Storage Linux Firmware - Lenovo Support U | all-1.50.30-0 |
All Supported Solid State Drives | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | ||||||||||
Lenovo Storage Linux Firmware - Lenovo Support U | all-1.50.30-0 |
ThinkSystem RAID 9350-8i 2GB Flash PCIe 12Gb Adapter | Lenovo Part Number: 4Y37A84028 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: Miss | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Lenovo Storage Adapter Linux Firmware - Lenovo Support U | smartpqi.350-5.91-2 | 5.91 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
No DS number available | smartpqi-20230912-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS/SATA-RAID | 0x9005 | 0x028F | 0x1D49 | 0x0620 | smartpqi | 70.4440.0.124 |
Back to Index
ThinkSystem RAID 5350-8i PCIe 12Gb Adapter | Lenovo Part Number: 4Y37A84028 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: Miss | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Lenovo Storage Adapter Linux Firmware - Lenovo Support U | smartpqi.350-5.91-2 | 5.91 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
No DS number available | smartpqi-20230912-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS/SATA-RAID | 0x9005 | 0x028F | 0x1D49 | 0x0520 | smartpqi | 70.4440.0.124 |
Back to Index
ThinkSystem 4350-8i SAS/SATA 12Gb HBA | Lenovo Part Number: 4Y37A84028 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: Miss | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Lenovo Storage Adapter Linux Firmware - Lenovo Support U | smartpqi.350-5.91-2 | 5.91 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
No DS number available | smartpqi-20230912-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
SAS | 0x9005 | 0x028F | 0x1D49 | 0x0220 | smartpqi | 70.4440.0.124 |
Back to Index
QLogic 16Gb Enhanced Gen5 FC Dual-port HBA | Lenovo Part Number: 01CV760 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: ATZC | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Marvell Qlogic Fibre Channel Adapter Linux Firmware - Lenovo Support U | qla-2690.2700-1.94.10-0 | Query Error | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Marvell-Qlogic Fibre Channel | qla-20230618-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x1077 | 0x2261 | 0x1077 | 0x02AF | ||||||||
Fibre Channel | 0x1077 | 0x2261 | 0x1077 | 0x02AF | Driver Query Error | Error |
Back to Index
QLogic 16Gb Enhanced Gen5 FC Single-port HBA | Lenovo Part Number: 01CV750 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: ATZB | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Marvell Qlogic Fibre Channel Adapter Linux Firmware - Lenovo Support U | qla-2690.2700-1.94.10-0 | Query Error | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
Marvell-Qlogic Fibre Channel | qla-20230618-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Fibre Channel | 0x1077 | 0x2261 | 0x1077 | 0x02AE | ||||||||
Fibre Channel | 0x1077 | 0x2261 | 0x1077 | 0x02AE | Driver Query Error | Error |
Back to Index
ThinkSystem QLogic QL41134 PCIe 10Gb 4-Port Base-T Ethernet Adapter | Lenovo Part Number: 4XC7A76758 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: Miss | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
QLogic FastLinQ Ethernet Adapter Firmware Update for Linux | fl.ah-8.55.18-1 | 8.55.18 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
QLogic FastlinQ driver for VMware | fl-20210702-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Networking | 0x1077 | 0x8070 | 0x1077 | 0x0035 | qedrntv Required Support vib | 3.40.35.0 | qedentv Non compliant | 3.40.36.0 | ||||
Network (SRIOV) | 0x1077 | 0x8090 | 0x1077 | 0x0035 | qedrntv Required Support vib | 3.40.35.0 | qedentv Non compliant | 3.40.36.0 |
Back to Index
ThinkSystem QLogic QL41262 PCIe 25Gb 2-Port SFP28 Ethernet Adapter | Lenovo Part Number: 4XC7A08228 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: B21R | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
QLogic FastLinQ Ethernet Adapter Firmware Update for Linux | fl.ah-8.55.18-1 | 8.55.18 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
QLogic FastlinQ driver for VMware | fl-20210702-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
FCoE CNAs | 0x1077 | 0x8080 | 0x1077 | 0x0039 | qedf Non compliant | 2.2.62.0 | qedentv Required Support vib | 3.40.36.0 | ||||
iSCSI | 0x1077 | 0x8084 | 0x1077 | 0x0039 | qedentv Required Support vib | 3.40.36.0 | qedi Non compliant | 2.19.59.0 | ||||
Networking | 0x1077 | 0x8070 | 0x1077 | 0x0039 | qedrntv Required Support vib | 3.40.35.0 | qedentv Non compliant | 3.40.36.0 | ||||
Network (SRIOV) | 0x1077 | 0x8090 | 0x1077 | 0x0039 | qedrntv Required Support vib | 3.40.35.0 | qedentv Non compliant | 3.40.36.0 |
Back to Index
Mellanox ConnectX-4 Lx 2x25GbE PCIe Adapter | Lenovo Part Number: 4XC7A08315 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lenovo Feature Code: Miss | ||||||||||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Lenovo Firmware Package Version | Device Firmware Version | |||||||||
Nvidia-Mellanox ConnectX Networking Adapter/Device Linux Firmware - Lenovo Support U | cx-5.9-0.5.6.0-6 | 14.32.1010 | ||||||||||
Drivers | Lenovo Driver Package Description - Download Page Link (lenovo.com) | Lenovo Package Version | ||||||||||
No DS number available | cx-20230914-vc | |||||||||||
Device Function (VMware HCL link) | PCIe | Driver Name | Driver Version | |||||||||
VID | DID | SVID | SSID | |||||||||
Networking | 0x15B3 | 0x1015 | 0x15B3 | 0x0057 | nmlx5-core | 4.22.73.1004 | nmlx5-rdma Required Support vib | 4.22.73.1004 |
Back to Index
Lenovo Data Center Group VMware OS Support Home Page |
https://vmware.lenovo.com |